Part E: Installing Entry Energised End Cap (4)
STEP E1: Cap entry with energised end cap (4)
Ensure keyways are aligned and engage end cap (4) to entry (2) by hand. Hand tighten the end cap.
Using a wrench to ensure that the entry cannot turn, use a second wrench to ensure the end cap is wrench tight.
It is now permitted to energise the equipment.
2
Part F: Installing Body Energised End Cap
STEP F1: Tighten Middlenut (11)
Gripping the centrenut (6) ensuring it cannot turn, use a wrench to tighten the middlenut (11) until it is wrench tight.
6
STEP F2: Install and inspect backnut (12)
Tighten the backnut (12) until a seal is formed around the cable. Use a wrench/spanner to grip the middlenut (11). While preventing the
middlenut (11) turning, use a second wrench to apply one further full turn to the backnut (12). Use the middlenut guide as an indication
that the backnut is in the correct position to suit cable diameter. A diameter scale is printed into the border of this document to assist in
this process.
STEP F3: Install Body Energised End Cap (13)
Ensure keyways are aligned and engage body to end cap (13) by hand. Hold the centrenut (6) and hand tighten the end cap (13).
Using a wrench to ensure that the centrenut (6) cannot turn, use a second wrench to ensure the end cap (13) is wrench tight
13
AI 2045 - Issue B / Page 8 of 9
Align Keyways
4
11
Grip here
with wrench
11
Grip here
with wrench
6
12
Grip here
with wrench
Grip here
with wrench