Download Print this page

Hawke 501/RCG Product Assembly Instructions page 7

Hide thumbs Also See for 501/RCG:

Advertisement

Part D: Decoupling 501/RCG Entry From Body
WARNING: DO NOT DECOUPLE WHEN ENERGISED. SYSTEM MUST BE DE-ENERGISED WHEN COMMENCING THIS PROCEDURE
CAUTION: DO NOT UNDO CENTRENUT (6) UNTIL PRODUCT IS DECOUPLED. UNDOING THE CENTRENUT WHILST ENGAGED RISKS DAMAGE
TO THE PRODUCT.
STEP D1: Loosen Backnut (12)
Grip the middlenut (11) with a wrench, ensuring it cannot turn. Use a second wrench to undo the backnut (12) until loose
(minimum 2 turns).
STEP D2: Loosen Middlenut (11)
Grip the centrenut (6) with a wrench, ensuring it cannot turn. Use a second wrench to undo the middlenut (11) and slide
middlenut (11) and backnut (12) down the cable.
Grip here with wrench
STEP D3: Disconnect Body from Entry
Once the middlenut (11) is undone, the body will slide out from the entry.
STEP D4: Remove Centrenut (6)
Grip the entry (2) with a wrench, ensuring it cannot turn. Use a second wrench to undo the centrenut (6) and remove.
Entry (2) may now be tted with an alternative 501/RCG Body or capped.
2
Grip here
with wrench
AI 2045 - Issue B / Page 7 of 9
11
Grip here with wrench
11
6
6
12
12
Images for illustration purposes only.
Product supplied may di er from that shown.

Advertisement