STEP B2: Remove socket insert (7) from spigot (9)
Squeeze base of insert (7) and remove from the spigot (9) as shown.
STEP B3: Slide spigot (9) onto cable
Push spigot shoulder up to armour/braid. Slide clamping ring (10) up to the armour/braid by hand
9
STEP B4: Clamp Armour/Braid
Slide centrenut (6) over cable until it meets the spigot. Slide middlenut (11) up to centrenut and hand tighten.
Grip the centrenut (6) with a spanner/wrench. Use a second spanner/wrench to tighten half to three quarters of a turn.
6
Grip here
with wrench
STEP B5: Inspect Armour/Braid
Unscrew the middlenut (11). The armour clamp ring (10) should now be locked in place.
Visually inspect that the armour/braid has been successfully clamped between the spigot (9) and the armour clamp ring (10). If clamping is
not satisfactory, repeat step B4.
Cut inner sheath in line with edge of spigot (9) and strip to expose cores.
6
STEP B6: Fit socket insert
Take socket insert (7) and review numbering on tip. Feed cable cores through the correct slot in the socket insert. Slide the socket insert (7)
down to the spigot (9) until it clicks in place.
7
AI 2045 - Issue B / Page 4 of 9
10
11
9
10
7
*Click*
11
9
7
9
Images for illustration purposes only.
Product supplied may di er from that shown.

Advertisement