Mounting Without Mounting Flange; Mounting With Mounting Flange; Pneumatic Connection; Connecting The Control Medium - GEM Q30 Operating Instructions Manual

Pneumatically operated pinch valve
Hide thumbs Also See for Q30:
Table of Contents

Advertisement

10 Inspection and maintenance

9.3 Mounting without mounting flange

1. Before mounting the valve body, machine the housing in
accordance with the borehole pattern in the chapter "Di-
mensions" so that the valve body can be secured to the
housing.
2. Secure the valve body to the housing using four screws.
3. Re-attach or reactivate all safety and protective devices.

9.4 Mounting with mounting flange

1. Before mounting the actuator, machine the housing in ac-
cordance with the borehole pattern in the chapter "Dimen-
sions" so that the valve body can be guided through the re-
cess.
2. Guide the valve body through the recess in the housing.
The actuator's mounting flange must be flush with the
housing.
3. Connect the mounting flange and housing using appropri-
ate screws and washers (not included in the scope of de-
livery).

9.5 Pneumatic connection

The following types are available:
Normally closed (NC):
Actuator resting position: closed by spring force. Activation of
the actuator (connector 2) opens the actuator. When the actu-
ator is vented, the actuator is closed by spring force.
Normally open (NO):
Actuator resting position: opened by spring force. Activation
of the actuator (connector 4) closes the actuator. When the
actuator is vented, the actuator is opened by spring force.
Control function
Control medium
connector 2 (open)
1 (NC)
2 (NO)
+ = available
– = not available

9.5.1 Connecting the control medium

1. Use suitable connectors.
2. Connect the control medium lines tension-free and
without any bends or knots.
Thread size of the control medium connectors: G1/4
Control function
1
Normally closed (NC)
2
Normally open (NO)
GEMÜ Q30
Control medium
connector 4 (close)
+
-
+
Connections
2: Control medium
(open)
4: Control medium
(close)
4
2
3. If necessary, remove blanking plugs from the control me-
dium connectors.
4. Control function 1: Screw the control medium line into
control medium connector 2 of the actuator.
5. Control function 2: Screw the control medium line into
control medium connector 4 of the actuator.
10 Inspection and maintenance
The equipment is subject to pressure!
▶ Risk of severe injury or death.
Depressurize the plant.
Completely drain the plant.
Use of incorrect spare parts!
▶ Damage to the GEMÜ product.
▶ Manufacturer liability and guarantee will be void.
Use only genuine parts from GEMÜ.
Hot plant components!
▶ Risk of burns.
Risk of crushing!
▶ Risk of severe injury!
Requirements for tube lines used!
▶ Use tube lines suitable for the application, see manufac-
turer's information.
Only use undamaged tube lines.
14 / 19
WARNING
CAUTION
CAUTION
Only work on plant that has cooled
down.
CAUTION
Before performing any work on the
GEMÜ product, depressurize the plant.
NOTICE
www.gemu-group.com

Advertisement

Table of Contents
loading

Table of Contents