Installation – surface-mounted
Preparing the worktop
 Create the worktop cutout. Remem-
ber to maintain the minimum safety
distances (see "Installation – Safety
distances").
 Seal any cut surfaces on wooden
worktops with a special varnish, sil-
icone sealant or resin to prevent the
wood from swelling as a result of
moisture ingress. The sealant must
be heat-resistant.
Make sure that the sealant does not
come into contact with the top of the
worktop.
Fitting the spacer bars
Use the middle screw holes if one of the
following SmartLine elements is in-
stalled to the right or left of the spacer
bar: CS 7611, CS 7641, CS 7101(-1),
CS 7102(-1)
Wooden worktops
 Position the spacer bars flush onto
the upper edge of the cutout.
 Secure the spacer bars with the
3.5 x 25 mm wood screws supplied.
Natural stone worktops
You will need heavy-duty double-
sided tape (not supplied) to secure the
spacer bars.
 Stick the tape along the top edge of
the worktop cutout.
 Position the spacer bars flush onto
the upper edge of the cutout.
 Press the spacer bars firmly into
place.