Precautions For Handling Units For Use With R410A - Mitsubishi Electric CITY MULTI PAC-AH001-1 Service Manual

Ahu controller
Hide thumbs Also See for CITY MULTI PAC-AH001-1:
Table of Contents

Advertisement

ŒThoroughly read the following safety precautions prior to installation.
ŒObserve these safety precautions for your safety.
ŒThis equipment may have adverse effects on the equipment on the same power supply system.
ŒContact the local power authority before connecting to the system.
Symbol explanations
WARNING

Precautions for handling units for use with R410A

This symbol indicates that failure to follow the instructions exactly as stated poses the risk of serious injury or death.
CAUTION
This symbol indicates that failure to follow the instructions exactly as stated poses the risk of serious injury or dam-
age to the unit.
• Do not use the existing refrigerant piping.
– A large amount of chlorine that may be contained in the residual refrigerant and refrigerator oil in the existing piping may cause the refrigerator oil in the new unit to
deteriorate.
Indicates an action that must be avoided.
• Use refrigerant piping materials made of phosphorus deoxidized copper. Keep the inner and outer surfaces of the pipes clean and free of such contaminants as sulfur,
oxides, dust, dirt, shaving particles, oil, and moisture.
Indicates important instructions.
– Contaminants in the refrigerant piping may cause the refrigerator oil to deteriorate.
• Store the piping materials indoors, and keep both ends of the pipes sealed until immediately before brazing. (Keep elbows and other joints wrapped in plastic.)
Indicates a parts that requires grounding.
– Infiltration of dust, dirt, or water into the refrigerant system may cause the refrigerator oil to deteriorate or cause the compressor to malfunction.
• Use a small amount of ester oil, ether oil, or alkyl benzene to coat flares and flanges.
Indicates that caution must be taken with rotating parts. (This symbol is on the main unit label.) <Color: Yellow>
– Infiltration of a large amount of mineral oil may cause the refrigerator oil to deteriorate.
Indicates that the parts that are marked with this symbol pose a risk of electric shock. (This symbol is on the main
• Charge the system with refrigerant in the liquid phase.
unit label.) <Color: Yellow>
– If gaseous refrigerant is drawn out of the cylinder first, the composition of the remaining refrigerant in the cylinder will change and become unsuitable for use.
• Only use R410A.
WARNING
– The use of other types of refrigerant that contain chloride may cause the refrigerator oil to deteriorate.
Carefully read the labels affixed to the main unit.
• Use a vacuum pump with a check valve.
– If a vacuum pump that is not equipped with a check valve is used, the vacuum pump oil may flow into the refrigerant cycle and cause the refrigerator oil to deteriorate.
WARNING
• Prepare tools for exclusive use with R 410A. Do not use the following tools if they have been used with the conventional refrigerant: gauge manifold, charging hose, gas
leak detector, check valve, refrigerant charge base, vacuum gauge, and refrigerant recovery equipment.
Do not use refrigerant other than the type indicated in the
– If the refrigerant or the refrigerator oil that may be left on these tools are mixed in with R410A, it may cause the refrigerator oil in the new system to deteriorate.
manuals provided with the unit and on the nameplate.
Infiltration of water may cause the refrigerator oil to deteriorate.
Leak detectors for conventional refrigerants will not detect an R410A leak because R410A is free of chlorine.
Doing so may cause the unit or pipes to burst, or result in
explosion or fire during use, during repair, or at the time of
• Do not use a charging cylinder.
disposal of the unit.
– If a charging cylinder is used, the composition of the refrigerant in the cylinder will change and become unsuitable for use.
It may also be in violation of applicable laws.
• Exercise special care when handling tools for use with R410A.
MITSUBISHI ELECTRIC CORPORATION cannot be held
– Infiltration of dust, dirt, or water into the refrigerant system may cause the refrigerator oil to deteriorate.
responsible for malfunctions or accidents resulting from the
use of the wrong type of refrigerant.
Ask your dealer or a qualified technician to install the unit.
Improper installation by the user may result in water leak-
age, electric shock, or fire.
Properly install the unit on a surface that can withstand its
weight.
Unit installed on an unstable surface may fall and cause in-
jury.
Only use specified cables. Securely connect each cable so
that the terminals do not carry the weight of the cable.
Improperly connected cables may produce heat and start a
fire.
HWE13010
PAC-AH001-1
Take appropriate safety measures against wind gusts and
earthquakes to prevent the unit from toppling over.
Improper installation may cause the unit to topple over and
cause injury or damage to the unit.
Only use accessories (i.e., air cleaners, humidifiers, electric
heaters) recommended by Mitsubishi Electric.
Do not make any modifications or alterations to the unit.
Consult your dealer for repair.
Improper repair may result in water leakage, electric shock,
or fire.
Do not touch the heat exchanger fins with bare hands.
The fins are sharp and pose a risk of cuts.
In the event of a refrigerant leak, thoroughly ventilate the
room.
If gaseous refrigerant leaks out and comes in contact with
an open flame, toxic gases will be generated.
Properly install the unit according to the instructions in the
Installation Manual.
Improper installation may result in water leakage, electric
shock, or fire.
i i
7
GB
© 2018 Mitsubishi Electric US, Inc.

Hide quick links:

Advertisement

Table of Contents
loading