Gas - Meritus
Table 10
Gas Type
Natural gas H G20
LPG G30/G31
C
= Inlet pressure point
D
= Gas pipe
E
= Flexible pipe
G
= Inlet gas connection
M = Manometer
R
= Gas tap
Gas Conversion
1.
Only professional and qualified mechanic can do this job.
2.
By looking "Adjustment", replace Main Burner Injectors, Pilot Burner Injectors, and adjust correctly
Primary Air Setting for each Main Burner.
3.
Spare injectors are available with the appliance.
4.
Make sure the diameter printed on each injector in 1/100 of a millimeter.
5.
Convert the appliance after turn the gas OFF and in UP position and let Gas Range Series cool.
Important! On completion of the operation, make sure that there are no gas leaks or
malfunctions
NAYATI
Gas Pressure (mbar)
Normal
Minimum
20
17
28 / 37
20/25
Fig. 14
27
FRM-PDE-03-04
GB – Gas Range Series
Maximum
25
35/45
20151125