Gas Supply Connection - NAYATI NGER 4-60 Installation, Operation And Maintenance Instructions

Gas economic range nger 60 series nger 70 series nger 130 series
Table of Contents

Advertisement

• Gas Supply Connection

-
Before installing and connecting Gas Economic Range to gas supply, carefully control
the fixed part of gas system, which conformed to National Building Regulation.
-
Verify gas pipes sections to guarantee sufficient supply for all gas heated appliances.
Install it in similar condition to avoid excessive pressure drops.
-
The pipes must be made of steel (with junctions made using white cast iron, or
galvanized steel fittings, or autogenously welded joints) or copper pipes (with
mechanical joints and couplings without seals or mastics or brazed joints).
-
Control the gas bottle (if any) placed correctly and protected in dry area.
-
Check whether the gas pipes can easily inspected. If the pipes installed in floor and wall,
make sure that this work done according to professional standard with reference points
that make it possible to find the pipes.
-
Before installing Gas Economic Range, makes sure that it is set for the gas and
pressure (see Technical Data Plates). Consult the paragraph "Gas Conversion."
-
Connect Gas Economic Range to gas supply using solid fittings or flexible steel pipes
with suitable sections related to nominal power and length.
-
Check whether the flexible pipes does not pass or near hot surfaces, put under stress
and traction, contact with sharp edges, or other things that could damage the pipe.
-
Install quick ON – OFF valve between the gas mains and each single appliance where
easy to reach.
-
After install Gas Economic Range safely, take a pressure test the whole gas circuit by
using leak finder spray or non-corrosive foams.
ORIENTAL
Instructions Manual for Gas Economic Range
NAYATI
34
20141104