Position And Fixing; Gas Supply Connection - NAYATI NGR 8-75 Installation, Operation And Maintenance Instructions

Table of Contents

Advertisement

Gas - Meritus

Position and Fixing

1.
Authorized personnel must do the installation.
2.
Install the appliance according to National Safety Standard about gas-heated standard.
3.
Place the appliance in good ventilated room with permanent ventilation ducts to guarantee
sufficient exchange of air and keep the work place healthy.
4.
If the Gas Range Series not connected to a flue, it is recommended to install it under efficient
hood, which could evacuate burned gases and cooking steams. Below is construction type
according to National Regulations:
A
: Appliance without fan and does not have connection to a flue or to a device for evacuating
1
combustion products outside the room. The combustion air and burned gas mixed in one room.
5.
Make sure that any object around or under Gas Range Series does not obstruct air volume
required for combustion.
6.
Put away any flammable materials near Gas Range Series.
7.
When the appliance is freestanding, keep a distance at least 10 cm from side, and rear walls.
Especially when the appliance close to wall and does not protected with fire-resistant materials
made.
8.
Install the appliance separately or side by side with other appliance according to recommended
range.
9.
Put Gas Range Series on solid, flat, and horizontal floor.
10. Adjust the height of the four feet by using brackets.
11. Before turn the appliance ON, remove the protective film. Remove any adhesive with appropriate
solvent. Eliminate all packaging material according to national laws.

Gas Supply Connection

1.
Before installing and connecting Gas Range Series to gas supply, carefully control the fixed part
of gas system, which conformed to National Building Regulation.
2.
Verify gas pipes sections to guarantee sufficient supply for all gas heated appliances. Install it in
similar condition to avoid excessive pressure drops.
3.
The pipes must be made of steel (with junctions made using white cast iron, or galvanized steel
fittings, or autogenously welded joints) or copper pipes (with mechanical joints and couplings
without seals or mastics or brazed joints).
4.
Control the gas bottle (if any) placed correctly and protected in dry area.
5.
Check whether the gas pipes can easily inspected. If the pipes installed in floor and wall, make
sure that this work done according to professional standard with reference points that make it
possible to find the pipes.
NAYATI
25
FRM-PDE-03-04
GB – Gas Range Series
20151125

Advertisement

Table of Contents
loading

Table of Contents