Specifications - Mitsubishi Electric EHPT20Q-VM2EA Service Manual

Cylinder unit
Hide thumbs Also See for EHPT20Q-VM2EA:
Table of Contents

Advertisement

3

SPECIFICATIONS

Modes
Nominal thermal store tank volume
Overall unit dimensions
Weight (empty)
Weight (full)
Primary expansion vessel
Nominal volume
(Accessory item)
Charge pressure
Safety device
Water circuit
(Thermal store tank)
Booster heater
Primary circuit circulating
Thermal store and space heating
pump
Hot water supply
Connections
Primary circuit
Secondary (potable) circuit
Target temperature range
Space heating
DHW supply maximum temperature
Guaranteed operating range
Ambient *2
Outdoor temperature
Electrical data
Control board
Booster heater
Sound power level
Maximum secondary (potable) water supply pressure
Maximum primary working pressure
Minimum primary working pressure
*1 Depending on the ambient conditions, it may not reach the set temperature.
*2 The cylinder's environment MUST be frost-free.
GCH15010
Control thermistor (THW1)
Control thermistor (THW3)
Pressure relief valve (2 No. devices)
Flow sensor
Manual reset thermostat
Manual reset thermostat
Thermal Cut-out
(for dry run prevention)
Flow temperature *1
Room temperature
Power supply
(Phase, voltage, frequency)
Current
Breaker
(Local supply)
Power supply
(Phase, voltage, frequency)
Capacity
Current
Breaker
4
EHPT20Q-VM2EA
Space & DHW heating
200 L
1600 × 595 × 680 mm (Height × Width × Depth)
77 kg
283 kg
18 L
1.0 bar (100 kPa)
42 - 72°C
80 °C
3.0 bar (300 kPa)
Min. flow 1.3 L/min
90 °C
90 °C
121 °C
Grundfos Solar PML 25-145 180
Grundfos Solar PML 25-145 180
φ 22.0
φ 22.0
25 - 60 °C
10 - 30 °C
40 - 70 °C
0 - 35 °C (80%RH)
- 15 - 35 °C
230V N〜 50 Hz
12.8 A
20 A
230V N〜 50 Hz
2 kW
8.7 A
16 A
40 dB(A)
10 bar (1 MPa)
2.5 bar (250 kPa)
1.0 bar (100 kPa)