3

SPECIFICATIONS

Model name
Overall unit dimensions
Weight (empty)
Weight (full)
Plate heat exchanger
Unvented expansion vessel
(Primary circuit)
Safety device Water circuit
(Primary)
Booster heater
Primary circuit circulating Pump
Connections
Operating ambient condition
Electrical data
Optional extras
• Wireless Remote Controller
• Wireless Receiver
• Remote sensor
Nominal volume
Charge pressure
Control thermistor
Pressure relief valve
Flow switch
Control thermistor
Manual reset thermostat
Thermal Cut Off (for dry run prevention)
Water
Refrigerant
Liquid
(R410A)
Gas
Control board
Power supply
(Phase, voltage, frequency)
Breaker
(*when powered from
independent source)
Booster heater Power supply
(Phase, voltage, frequency)
Capacity
Current
Breaker
PAR-WT40R-E
• Joint pipe (15.88 → 12.7)
PAR-WR41R-E
• Joint pipe (9.52 → 6.35)
PAC-SE41TS-E
EHSC-VM6A
800 × 530 × 360 mm (Height × Width × Depth)
54 kg
60 kg
Grundfos UPSO 25-70 180
28 mm compression primary circuit
9.52 mm
15.88 mm
0 (*1) - 35°C ( 80 %RH)
~/N, 230 V, 50 Hz
2 kW+4 kW
26 A
32 A
PAC-SH50RJ-E
PAC-SH30RJ-E
7
EHSC-YM9A
EHPX-VM2A
54 kg
39 kg
60 kg
44 kg
10 L
0.1 MPa (1 bar)
1 - 80°C
0.3 MPa (3 bar)
Min fl ow 5.5 l/min
80°C
90°C
121°C
9.52 mm
15.88 mm
~/N, 230 V, 50 Hz
10A
3~, 400 V, 50 Hz
~/N, 230 V, 50 Hz
3 kW+6 kW
2 kW
13 A
16 A
*1 The environment must be frost-free.
9 A
16 A