Specifications - Extech Instruments 700 Series User Manual

800 amp clamp meters
Table of Contents

Advertisement

Specifications

Range &
Function
Resolution
AC Current
40.00A AC
50/60 Hz
400.0A AC
True RMS on
800A AC
EX720 & EX730
40.00A DC
DC Current
400.0A DC
EX730 only
800A DC
400.0mV AC
AC Voltage
4.000V AC
50/60Hz
40.00V AC
True RMS on
400.0V AC
EX720 & EX730
600V AC
400.0mV DC
4.000V DC
DC Voltage
40.00V DC
400.0V DC
600V DC
400.0Ω
4.000kΩ
40.00kΩ
Resistance
400.0kΩ
4.000MΩ
40.00MΩ
4.000nF
40.00nF
400.0nF
4.000µF
Capacitance
40.00µF
400.0µF
4.000mF
40.00mF
4.000kHz
Frequency
Sensitivity: 100V (<50Hz); 50V (50 to 400Hz); 5V (401 to 4000Hz)
(% of reading + digits)
EX710
± (2.8% + 10d)
± (2.5% + 10d)
± (2.8% + 8d)
± (3.0% + 8d)
NA
± (1.5% + 10d)
± (1.0% + 10d)
± (1.8% + 8d)
± (2.5% + 8d)
± (0.8% + 2d)
± (1.5% + 2d)
± (2.0% + 2d)
± (1.0% + 4d)
± (1.5% + 2d)
± (2.5% + 3d)
± (3.5% + 5d)
± (5.0% + 30d)
± (5.0% + 30d)
± (5.0% + 20d)
± (5.0% + 20d)
± (3.0% + 5d)
± (4.0% + 10d)
± (4.0% + 10d)
± (10% + 10d)
± (10% + 10d)
unspecified
± (1.5% + 2d)
5
Accuracy
EX720
± (5% + 10d)
± (2.5% + 8d)
± (5% + 10d)
± (2.8% + 5d)
± (2.8% + 10d)
± (5% + 10d)
NA
± (5% + 10d)
± (2.8% + 10d)
± (1.0% + 10d)
± (1.5% + 5d)
± (1.5% + 5d)
± (2.0% + 5d)
± (2.0% + 5d)
± (0.8% + 2d)
± (0.8% + 2d)
± (1.5% + 2d)
± (1.5% + 2d)
± (2.0% + 2d)
± (2.0% + 2d)
± (1.0% + 4d)
± (1.0% + 4d)
± (1.5% + 2d)
± (1.5% + 2d)
± (2.5% + 3d)
± (2.5% + 3d)
± (3.5% + 5d)
± (3.5% + 5d)
± (5.0% + 30d)
± (5.0% + 20d)
± (3.0% + 5d)
± (3.0% + 5d)
± (4.0% + 10d)
± (10% + 10d)
unspecified
unspecified
± (1.5% + 2d)
± (1.5% + 2d)