Protection class (Grade):
Environment class:
Target speed range:
Main features:
Power supply:
Operation temp:
Color:
Weight:
Dimensions:
Manufacturer / Brand:
SAP Code:
Manufacturer's code:
Guarantee:
DELTA-OPTI Monika Matysiak; https://www.delta.poznan.pl
POL; 60-713 Poznań; Graniczna 10
e-mail: delta-opti@delta.poznan.pl; tel: +(48) 61 864 69 60
2021-07-04
User Manual
Code: KX15DT1
DUAL TECHNOLOGY DETECTOR MICROWAVE + PIR KX15DT1 PYRONIX
Grade 2
II
0.3 ... 3.0 m/s
• EN50131-2-2:2008, EN50131-1:2006+A1:2009, PD6662:2010
• digital detection algorithm with temperature compensation for high immunity to
false alarms and repeatability of parameters
• Smooth adjustment of microwave range
• Immunity to environmental changes
• Independent Floating Threshold (IFT) technology
• Creep zone control
• Tamper detection - opening the enclosure, removing from mounting surface
• The set includes a ceiling and wall bracket
9 ... 16 V DC / 30 mA (max) @ 12 V
-30 °C ... 70 °C
White
0.12 kg
116 x 68 x 51 mm
PYRONIX
361301740
KX15DT
5 years
Internal view:
KX15DT1
3/5
Need help?
Do you have a question about the KX15DT1 and is the answer not in the manual?