Manual FS 12‐100‐1 M G8‐B8‐PB and FS 12‐100‐2 M G8‐B8‐PB Version 1.1 di‐soric GmbH & Co. KG Steinbeisstraße 6 DE‐73660 Urbach Germany +49 (0) 71 81 / 98 79 ‐ 0 +49 (0) 71 81 / 98 79 ‐ 179 info@di‐soric.com ...
Page 2
CR200P and CR210P Manual Content Notes The information contained in this manual has been thoroughly researched and prepared. Nevertheless, we cannot assume liability for omissions or errors of any nature whatsoever. We would, however, be grateful for your comments or suggestions. We shall not accept any claims for damages, except for those resulting from intent or gross negligence. As this product is available in several designs, there might be deviations between the descriptions and instructions in hand and the product supplied. We reserve the right to make technical changes, which serve to improve the product, without prior notification. Thus, it cannot be assumed that subsequent versions of a product will have the same features as ...
CR200P and CR210P Manual Technical Data Technical Data Table 1 : General technical data Sensing channels FS 12‐100‐2 M G8‐B8‐PB: 2 Sensing channels FS 12‐100‐1 M G8‐B8‐PB: 1 Sensing channel, 1 Internal stab. channel Drift stabilization CROMLASTAB®, Can be switched off Receiving detector Three range photo diode Sensitivity Adjustable by user Sensitivity steps 8 (1x, 4x, 20x, 40x, 80x, 200x, 400x, 800x) Receiving signal resolution 3 x 4096 steps Object illumination Power white light LED Adjustable (4096 Steps) Can be switched off Ambient light compensation Can be switched off Standard interfaces 12 Switching outputs 2 Control inputs Serial (RS‐232) USB Field bus interface Profibus Displays 19 LEDs for outputs and status Buttons 3 Buttons for Teach‐In Color resolution (L*a*b*) ∆E ≤ 1 Lab Response time ...
Page 5
Technical Data CR200P and CR210P Manual Table 2 : Operational functionality Channel measurement methods FS 12‐100‐2 M G8‐B8‐PB: Difference measurement Channel 1 Channel 1 drift compensated Channel 1+2 FS 12‐100‐1 M G8‐B8‐PB: Channel 1 Channel 1 drift compensated Color space modes Non‐self‐shining objects XYZ, XyY, u'v'L*, L*a*b*, xyl Self‐shining objects XYZ, xyY, u'v'L*, xyl Color recognition modes Check spherical tolerance Check cylindrical tolerance Minimal distance Operating modes External triggering Color grouping Color sequence recognition Parameterization Elaborately via PC Software Limited via 3 buttons di‐soric GmbH & Co. KG Page 5 ...
PROFIBUS DP CR200P and CR210P Manual PROFIBUS DP 3.1 General Color sensors that are equipped with the optional Profibus interface, can be easily integrated into existing bus systems. They work as Profibus standard slave and support baud rates up to 12 MBaud (autodetect). The Profibus address of the device is set via the bus master (e.g. Siemens PG or any master with SET_SLAVE_ADD). The default factory set address is 1. The user can choose the data, which is transferred to the Profibus master, via different modes. The possibilities range from status‐information and the current state of the switching outputs to the transfer of all color values, including the color detection result and the color distance. 3.2 Connections The sensor is connected to the bus via two standard circular connectors (Binder series 715, 4 pin, B coded). If only one of the two is connected (PB‐IN), the other is to be provided with a terminating resistor. The pin assignment of the connectors is shown in Table 10. Table 10 : Pin assignment of the Profibus connectors Description PB‐IN PB‐Out ...
Page 10
CR200P and CR210P Manual PROFIBUS DP 3.4 Profibus‐IN For the format of the input data there are three different modes available. The data is sent to the Profibus‐ master. Mode 1 In mode 1 the color sensor sends a life‐counter, status information and the current state of the switching outputs of the sensor to the bus. ...
Page 11
PROFIBUS DP CR200P and CR210P Manual Mode 3 Mode 3 outputs the data of mode 1, mode 2 and the color and recognition data of the sensors second measuring channel. This mode is only useful for the FS 12‐100‐2 M G8‐B8‐PB sensor. Only in this case the measuring channels are evaluated separately. ...
CR200P and CR210P Manual PROFIBUS DP 3.5 Profibus‐OUT Within all modes, two data bytes are transferred to the sensor with every bus‐cycle. The first byte specifies the table index for the controlled teach‐in of a color. The individual bits of the second byte are used to control the sensor. Table 14 provides an overview of the functions. Table 14 : Meaning of the control bits in the second Profibus‐Out‐Byte Bit Name Function 0 TRG 0 Control line to update the outputs 1 TRG 1 Control line for Teach‐In Teach‐In Mode 2 Teach 0 = as adjusted in the DSP 1 = TabIndex 3 Reserved 4 Reserved 5 Reserved 6 Reserved 7 Reserved ...
Drawings CR200P and CR210P Manual Drawings Figure 3 : Drawings FS 12‐100‐2 M G8‐B8‐PB for connecting two separate fiber optical cables di‐soric GmbH & Co. KG Page 15 ...
Page 16
CR200P and CR210P Manual Drawings Figure 4 : Drawings FS 12‐100‐1 M G8‐B8‐PB with built‐in control devices for the drift stabilization CROMLASTAB® Page 16 di‐soric GmbH & Co. KG ...
Displays CR200P and CR210P Manual Displays Table 15 : LED meaning LED Meaning O1‐O12 State output 1‐12 Stab. Error Stabilization 2‐Ch. Two channel operation Teach Teach‐in mode active Signal Signal mode active Sel. Sensing channel 2 active SET Tolerance Stat., Link, Error Interface specific Table 16 : Assignment of flash impulses to tolerance values Flash impulses Tolerance Tolerance value 1 Very small 3 2 Small 6 3 Medium 9 4 Large 15 5 ...
CR200P and CR210P Manual Button operation Button operation Automatic signal adjustment Position sensor to object Press "Mode" button shortly until "Sig." mode is active Press "SET" button for at least 2 seconds To store parameters press "Mode" button for at least 2 seconds Sample stabilization reference value Press "Mode" button shortly until "Sig." mode active Press "Sel." Button shortly to select stabilization channel Adjust signal level for stabilization channel mechanically (adjusting screw) Press "SET" button for at least 2 seconds To store parameters press "Mode" button for at least 2 seconds Teaching in colors Position sensor to object Press "Mode" button shortly until "Teach‐In" mode active Press "Sel." button to select table entry Press "SET" button for at least 2 seconds To store parameters press "Mode" button for at least 2 seconds Adjust tolerance Press "Mode" button shortly until "Teach‐In" mode active Press "SET" button shortly to select tolerance ...
Surge protection CR200P and CR210P Manual Surge protection To use the sensor in systems where the supply voltage line > 3 meters, it is recommenced to use a filter module to protect against surges. A suitable 24 V DC filter module (surge) is available from the company WAGO under order number 750‐626. di‐soric GmbH & Co. KG Page 19 ...
CR200P and CR210P Manual Declaration of Conformity Declaration of Conformity Manufacturer ASTECH Angewandte Sensortechnik GmbH Address 18057 Rostock Schonenfahrerstr. 5 Deutschland Product name FS 12‐100‐2 M G8‐B8‐PB/ FS 12‐100‐1 M G8‐B8‐PB Device description Color sensor EG Declaration of Conformity In accordance with the Directive of Electromagnetic compatibility 2004/108/EG Conforming to the following standards Radio disturbance characteristics: EN 61000‐6‐3:2007 EMC immunity EN 61000‐6‐2:2005 In addition the following standard is passed: EN 61326‐1:2006; Electrical equipment for measurement, control and laboratory use – EMC requirements; Classification: Class B (emission); Industrial equipment (immunity) Place Rostock Date Januar 2010 ...