Advertisement

Quick Links

 
 
FS 12‐100‐1 M G8‐B8‐PB and 
FS 12‐100‐2 M G8‐B8‐PB  
di‐soric GmbH & Co. KG 
Steinbeisstraße 6 
DE‐73660 Urbach 
Germany
 
 
+49 (0) 71 81 / 98 79 ‐ 0
 
 
 
+49 (0) 71 81 / 98 79 ‐ 179
 
 
 
info@di‐soric.com
 
 
 
 
 
 
Manual 
Version 1.1 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FS 12-100-1 M G8-B8-PB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Di-soric FS 12-100-1 M G8-B8-PB

  • Page 1       Manual  FS 12‐100‐1 M G8‐B8‐PB and  FS 12‐100‐2 M G8‐B8‐PB   Version 1.1  di‐soric GmbH & Co. KG  Steinbeisstraße 6  DE‐73660 Urbach  Germany     +49 (0) 71 81 / 98 79 ‐ 0         +49 (0) 71 81 / 98 79 ‐ 179         info@di‐soric.com        ...
  • Page 2 CR200P and CR210P Manual  Content    Notes  The  information  contained  in  this  manual  has  been  thoroughly  researched  and  prepared.  Nevertheless,  we  cannot assume liability for omissions or errors of any nature whatsoever. We would, however, be grateful for  your comments or suggestions.  We shall not accept any claims for damages, except for those resulting from intent or gross negligence.  As  this  product  is  available  in  several  designs,  there  might  be  deviations  between  the  descriptions  and  instructions in hand and the product supplied.  We  reserve  the  right  to  make  technical  changes,  which  serve  to  improve  the  product,  without  prior  notification. Thus, it cannot be assumed that subsequent versions of a product will have the same features as ...
  • Page 3: Table Of Contents

    Content  CR200P and CR210P Manual      Contents      Technical Data ..............................  4     Specification electrical interfaces  ........................  6     PROFIBUS DP ..............................  9     General ..............................  9     Connections ...............................  9     Data transfer  ..............................  9     Profibus‐IN  ...............................  1 0  ...
  • Page 4: Technical Data

    CR200P and CR210P Manual  Technical Data    Technical Data  Table 1 : General technical data  Sensing channels  FS 12‐100‐2 M G8‐B8‐PB: 2 Sensing channels  FS 12‐100‐1 M G8‐B8‐PB: 1 Sensing channel, 1  Internal stab. channel  Drift stabilization  CROMLASTAB®, Can be switched off  Receiving detector  Three range photo diode  Sensitivity  Adjustable by user  Sensitivity steps  8 (1x, 4x, 20x, 40x, 80x, 200x, 400x, 800x)  Receiving signal resolution  3 x 4096 steps  Object illumination  Power white light LED  Adjustable (4096 Steps)  Can be switched off  Ambient light compensation  Can be switched off  Standard interfaces  12 Switching outputs  2 Control inputs  Serial (RS‐232)  USB  Field bus interface  Profibus  Displays  19 LEDs for outputs and status  Buttons  3 Buttons for Teach‐In  Color resolution (L*a*b*)  ∆E ≤ 1  Lab  Response time ...
  • Page 5 Technical Data  CR200P and CR210P Manual     Table 2 : Operational functionality  Channel measurement methods  FS 12‐100‐2 M G8‐B8‐PB:  Difference measurement    Channel 1    Channel 1 drift compensated    Channel 1+2  FS 12‐100‐1 M G8‐B8‐PB:  Channel 1    Channel 1 drift compensated  Color space modes  Non‐self‐shining objects  XYZ, XyY, u'v'L*, L*a*b*, xyl  Self‐shining objects  XYZ, xyY, u'v'L*, xyl  Color recognition modes  Check spherical tolerance  Check cylindrical tolerance  Minimal distance  Operating modes  External triggering  Color grouping  Color sequence recognition  Parameterization  Elaborately via PC Software  Limited via 3 buttons        di‐soric  GmbH  & Co. KG  Page 5   ...
  • Page 6: Specification Electrical Interfaces

    CR200P and CR210P Manual  Specification electrical interfaces    Specification electrical interfaces  Figure 1 shows the electrical connectors (type M9) of the sensor.    Figure 1 : Electrical interfaces  The counting order of round connectors is shown in Figure 2.        Figure 2 : Counting order of the round connectors    Table 3 : Signal description sensor connector AB1  Pin (color)  Name  Description  1 (white)  OUT1  Sensor output 1  2 (brown)  OUT2  Sensor output 2  3 (green)  TRG1  Input for external triggered Teach‐In in mode "Ext. Teach"  4 (yellow)  TRG0  Input for updating the sensor outputs in mode "Extern Trig."  Input for trigger controlled color sequence in mode "Trig. Sequ."  5 (grey)  OUT3  Sensor output 3  6 (pink)  OUT4  Sensor output 4   7 (blue)  GND  Ground  8 (red)   ...
  • Page 7 Specification electrical interfaces  CR200P and CR210P Manual     Table 5 : Electrical specification sensor connector AB1  Pin  Specification  1 (OUT1)  Push‐Pull  LOW: 0 V; HIGHT: +U  ‐ 1 V; max. 100 mA  2 (OUT2)  Push‐Pull  LOW: 0 V; HIGHT: +U  ‐ 1 V; max. 100 mA  3 (TRG1)  LOW: 0 V ... 3 V; HIGH: 18 V ... 28 V  4 (TRG0)  LOW: 0 V ... 3 V; HIGH: 18 V ... 28 V  5 (OUT3)  Push‐Pull  LOW: 0 V; HIGHT: +U  ‐ 1 V; max. 100 mA  6 (OUT4)  Push‐Pull  LOW: 0 V; HIGHT: +U  ‐ 1 V; max. 100 mA  7 (GND)  0 V  8 (+U )  18 ... 28 VDC, max. 500 mA  (optional 9 ... 28 VDC)    Table 6 : Electrical specification sensor connector AB2  Pin  Specification  1 (OUT5)  Push‐Pull  LOW: 0 V; HIGHT: +U  ‐ 1 V; max. 100 mA ...
  • Page 8 CR200P and CR210P Manual  Specification electrical interfaces    Table 7 : RS‐232  Pin  Description  Specification  1 (GND)  GND  0 V  2 (TXD)  Send  ‐5 V ... +5 V  3 (RXD)  Receive  ‐5 V ... +5 V  4 (+U )  Optional voltage output  18 ... 28 VDC  Shield  Device shield (earth)  Earth    Table 8 : RS‐232 Parameters  Parameter  Value  Baud rate  9.600 ... 115.200  Data bits  8  Parity  no  Stop bits  1  Flow control  No  The baud rate of the RS‐232 interface is pre‐set to 28800.  Table 9 : USB  Pin  Description ...
  • Page 9: Profibus Dp

    PROFIBUS DP  CR200P and CR210P Manual     PROFIBUS DP  3.1 General  Color sensors that are equipped with the optional Profibus interface, can be easily integrated into existing bus  systems. They work as Profibus standard slave and support baud rates up to 12 MBaud (autodetect).  The  Profibus  address  of  the  device  is  set  via  the  bus  master  (e.g.  Siemens  PG  or  any  master  with  SET_SLAVE_ADD). The default factory set address is 1.  The user can choose the data, which is transferred to the Profibus master, via different modes. The possibilities  range from status‐information and the current state of the switching outputs to the transfer of all color values,  including the color detection result and the color distance.  3.2 Connections  The sensor is connected to the bus via two standard circular connectors (Binder series 715, 4 pin, B coded). If  only one of the two is connected (PB‐IN), the other is to be provided with a terminating resistor.  The pin assignment of the connectors is shown in Table 10.  Table 10 : Pin assignment of the Profibus connectors  Description  PB‐IN  PB‐Out ...
  • Page 10 CR200P and CR210P Manual  PROFIBUS DP    3.4 Profibus‐IN  For  the  format  of  the  input  data  there  are  three  different  modes  available.  The  data  is  sent  to  the  Profibus‐ master.  Mode 1  In  mode  1  the  color  sensor  sends  a  life‐counter,  status  information  and  the  current  state  of  the  switching  outputs of the sensor to the bus. ...
  • Page 11 PROFIBUS DP  CR200P and CR210P Manual     Mode 3  Mode  3  outputs  the  data  of  mode  1,  mode  2  and  the  color  and  recognition  data  of  the  sensors  second  measuring  channel.  This  mode  is  only  useful  for  the  FS  12‐100‐2  M  G8‐B8‐PB  sensor.  Only  in  this  case  the  measuring channels are evaluated separately. ...
  • Page 12: Profibus-Out

    CR200P and CR210P Manual  PROFIBUS DP    3.5 Profibus‐OUT  Within all modes, two data bytes are transferred to the sensor with every bus‐cycle. The first byte specifies the  table index for the controlled teach‐in of a color. The individual bits of the second byte are used to control the  sensor. Table 14 provides an overview of the functions.        Table 14 : Meaning of the control bits in the second Profibus‐Out‐Byte  Bit  Name  Function  0  TRG 0  Control line to update the outputs  1  TRG 1  Control line for Teach‐In  Teach‐In Mode  2  Teach  0 = as adjusted in the DSP  1 = TabIndex  3    Reserved  4    Reserved  5    Reserved  6    Reserved  7    Reserved ...
  • Page 13 PROFIBUS DP  CR200P and CR210P Manual       #Profibus_DP    GSD_Revision        = 1    ; Device identification  Vendor_Name         = "di‐soric"  Model_Name          = "FS 12‐100‐x"  Revision            = "V1.0"  Ident_Number        = 0x2079  Protocol_Ident      = 0  Station_Type        = 0  FMS_supp            = 0  Hardware_Release    = "Revision F"  Software_Release    = "V1.0"    ; Supported baudrates  9.6_supp            = 1  19.2_supp           = 1  93.75_supp          = 1  187.5_supp          = 1  500_supp            = 1  1.5M_supp           = 1  3M_supp             = 1  6M_supp             = 1  12M_supp            = 1    ; Maximum responder time for supported baudrates   MaxTsdr_9.6         = 60  MaxTsdr_19.2        = 60  MaxTsdr_93.75       = 60  MaxTsdr_187.5       = 60  MaxTsdr_500         = 100  MaxTsdr_1.5M        = 150  MaxTsdr_3M          = 250  MaxTsdr_6M          = 450  MaxTsdr_12M         = 800 ...
  • Page 14 CR200P and CR210P Manual  PROFIBUS DP      ; Maximum polling frequency  Min_Slave_Intervall = 1       ; 100 us    ; Maximum supported sizes  Modular_Station     = 1       ; modular  Max_Module          = 1  Max_Input_Len       = 244  Max_Output_Len      = 244  Max_Data_Len        = 432  Modul_Offset        = 0    Fail_Safe           = 0       ; state CLEAR not accepted  Slave_Family        = 9  Max_Diag_Data_Len   = 8    ; Definition of modules  Module = "M1: 2Out‐Word/2In‐Byte" 0xD1,0xE0  EndModule  Module = "M2: 8Out‐Word/2In‐Byte" 0xD7,0xE0  EndModule  Module = "M3: 14Out‐Word/2In‐Byte" 0xDD,0xE0  EndModule      ;============================================================        Page 14  di‐soric  GmbH  & Co. KG   ...
  • Page 15: Drawings

    Drawings  CR200P and CR210P Manual     Drawings      Figure 3 : Drawings FS 12‐100‐2 M G8‐B8‐PB for connecting two separate fiber optical cables    di‐soric  GmbH  & Co. KG  Page 15   ...
  • Page 16 CR200P and CR210P Manual  Drawings        Figure 4 : Drawings FS 12‐100‐1 M G8‐B8‐PB with built‐in control devices for the drift stabilization CROMLASTAB®        Page 16  di‐soric  GmbH  & Co. KG   ...
  • Page 17: Displays

    Displays  CR200P and CR210P Manual     Displays  Table 15 : LED meaning  LED  Meaning  O1‐O12  State output 1‐12  Stab.  Error Stabilization  2‐Ch.  Two channel operation  Teach  Teach‐in mode active  Signal  Signal mode active  Sel.  Sensing channel 2 active  SET  Tolerance  Stat., Link, Error  Interface specific  Table 16 : Assignment of flash impulses to tolerance values  Flash impulses  Tolerance  Tolerance value  1  Very small  3  2  Small  6  3  Medium  9  4  Large  15  5 ...
  • Page 18: Button Operation

    CR200P and CR210P Manual  Button operation    Button operation  Automatic signal adjustment   Position sensor to object   Press "Mode" button shortly until "Sig." mode is active   Press "SET" button for at least 2 seconds   To store parameters press "Mode" button for at least 2 seconds  Sample stabilization reference value   Press "Mode" button shortly until "Sig." mode active   Press "Sel." Button shortly to select stabilization channel   Adjust signal level for stabilization channel mechanically (adjusting screw)   Press "SET" button for at least 2 seconds    To store parameters press "Mode" button for at least 2 seconds  Teaching in colors   Position sensor to object   Press "Mode" button shortly until "Teach‐In" mode active   Press "Sel." button to select table entry   Press "SET" button for at least 2 seconds   To store parameters press "Mode" button for at least 2 seconds   Adjust tolerance   Press "Mode" button shortly until "Teach‐In" mode active   Press "SET" button shortly to select tolerance  ...
  • Page 19: Surge Protection

    Surge protection  CR200P and CR210P Manual     Surge protection  To use the sensor in systems where the supply voltage line > 3 meters, it is recommenced to use a filter module  to protect against surges. A suitable 24 V DC filter module (surge) is available from the company WAGO under  order number 750‐626.   di‐soric  GmbH  & Co. KG  Page 19   ...
  • Page 20: Declaration Of Conformity

    CR200P and CR210P Manual  Declaration of Conformity    Declaration of Conformity  Manufacturer  ASTECH Angewandte Sensortechnik GmbH  Address  18057 Rostock    Schonenfahrerstr. 5    Deutschland  Product name  FS 12‐100‐2 M G8‐B8‐PB/ FS 12‐100‐1 M G8‐B8‐PB  Device description  Color sensor    EG Declaration of Conformity  In accordance with the Directive of Electromagnetic  compatibility 2004/108/EG        Conforming to the following standards  Radio disturbance characteristics:  EN 61000‐6‐3:2007  EMC immunity  EN 61000‐6‐2:2005  In addition the following standard is passed:  EN 61326‐1:2006;   Electrical equipment for measurement, control and laboratory use –  EMC requirements;     Classification: Class B (emission);     Industrial equipment (immunity)  Place  Rostock  Date  Januar 2010   ...

This manual is also suitable for:

Fs 12-100-2 m g8-b8-pb