5.4

NON-COMBUSTIBLE FACING MATERIAL

WARNING: The appliance opening may be recessed in non-combustible facing material provided it does
EN
not project more than 2" (50.8mm) past the face of the appliance. If greater projections are desired,
increase the clearance to the sides and top by 2" (50.8mm) for every additional 1" (25.4mm) of projection.
If using an optional surround, then 2" (50.8mm) clearance from the surround is required before projecting
out a maximum 2" (50.8mm). If greater projections are desired, increase the clearance from the surround
by 2" (50.8mm) for every 1" (25.4mm) of additional projection.
A
A
6" (152.4mm)
4" (101.6mm)
2" (50.8mm)
W415-2180 / A / 11.28.16
4"
(101.6mm)
3" (76.2mm)
2" (50.8mm)
TOP OF
APPLIANCE
0" (0mm)
SAFETY
DOOR
BARRIER
SECTION A - A
B
B
6" (152.4mm)
4" (101.6mm)
2" (50.8mm)
0" (0mm)
SECTION B - B
71.5C
4" (101.6mm)
3" (76.2mm)
2" (50.8mm)
1" (25.4mm)
TOP OF
APPLIANCE
DOOR