Maintenance - Ryobi RY906500 Operator's Manual

6,500 watt generator
Table of Contents

Advertisement

Available languages

Available languages

Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified
repair establishment or individual with original or equivalent
parts. Warranty and recall repairs must be performed by an
authorized service center; please contact customer service
for assistance.
WARNING:
Before inspecting, cleaning, or servicing the machine,
shut off engine, wait for all moving parts to stop, and
disconnect spark plug wire and move it away from spark
plug. Allow 30 minutes of cool down time before perform-
ing any maintenance. Failure to follow these instructions
can result in serious personal injury or property damage.
WARNING:
When servicing, use only recommended or equivalent
replacement parts. Service or maintenance performed
by unqualified personnel or use of any other parts could
result in a personal injury hazard or property damage.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and
do not operate this product until all missing or damaged
parts are replaced. Please contact customer service or
a qualifed service center for assistance.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
 Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
 Clean air vents with low pressure air that does not exceed
25 psi.
 Wipe the exterior surfaces of the generator with a damp
cloth.
CHECKING/CLEANING AIR FILTER
See Figure 16.
For proper performance and long life, keep air filter clean.
 Release latches on side of air filter cover. Remove cover
and set aside.
 Remove the filter element.

MAINTENANCE

 If the filter element is dirty, clean with warm, soapy water.
Rinse and let dry.
 Apply a light coat of engine lubricant to the element, then
squeeze it out.
 Replace the element in the air filter unit.
 Replace the air filter cover and latch to secure.
NOTE: Do not run the generator without the air filter. Rapid
engine wear will result.
CHANGING ENGINE LUBRICANT
See Figure 17.
 Remove the oil cap/dipstick.
 Place a container underneath the oil drain plug to collect
used lubricant as it drains.
 Unscrew the oil drain plug and remove.
 Allow lubricant to drain completely.
NOTE: Drain the lubricant while the engine is still warm
but not hot. Warm lubricant will drain quickly and more
completely.
WARNING:
Do not change engine lubricant while it is hot. Accidental
contact with hot engine lubricant could result in serious
burns.
 Reinstall the oil drain plug and tighten securely.
 Refill with lubricant following the instructions in the
Checking/Adding Lubricant section. For amount of
lubricant needed to refill, see Product Specifications
earlier in this manual or the accompanying engine manual,
if applicable.
 Reinstall the oil cap/dipstick.
NOTE: Used lubricant should be disposed of at an approved
disposal site. See your local oil retailer for more information.
SPARK PLUG MAINTENANCE
See Figure 18.
The spark plug must be properly gapped and free of deposits
in order to ensure proper engine operation. To check:
 Remove the spark plug cap.
 Clean any dirt from around base of spark plug.
 Remove spark plug using wrench (not included).
 Inspect spark plug for damage, and clean with a wire
brush before reinstalling. If insulator is cracked or
chipped, spark plug should be replaced. For replacement
spark plug, see Product Specifications earlier in this
manual or the accompanying engine manual, if applicable.
 Measure plug gap. The correct gap is 0.028−0.031 in.
(0.7-0.8 mm). To widen gap, if necessary, carefully bend
the ground (top) electrode. To lessen gap, gently tap
ground electrode on a hard surface.
Page 15 — English

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents