Safety instructions Dear user Please note! Congratulations on your purchase of a Faber fire! A quality product from which you will experience It is advisable to always install a screen for the warmth and atmosphere for many years. We...
(fig. 1.0) is placed on the right C31, outlet via roof side of the crate for transport reasons. For a (flat) roof, use a Faber roof outlet with a Detach and mount it together with the diameter of 100/150mm.
Page 11
7 “Checking the installation”. The controller can be connected to an external source, such as a Domotica system, by using a False chimney Faber Interface Unit (article number A9323000). Construct the false chimney of non- combustible material in combination with 4.4 Preparing the fireplace...
Page 12
Installation manual Triple M,L Smart must be installed just above the ventilation The insert strip R can be removed by the supplied openings (see fig. 1.5-A or 1.6-A). magnet T (see fig. 3.1). Installation and finishing Removing glass Please note! 5.1 Front glass ...
Installation manual Triple M,L Smart Placing decoration material The pressure must correspond to the value indicated in the technical specifications of this manual. In case of Please note! deviation contact the manufacturer. It is not permitted to use other or to add more material in the combustion ...
Start length (STL): Remove the front glass (see chapter 5). The first part that is placed on the You can clean the glass with Faber glass polish. fireplace and represents a certain value This is a specially formulated cleaning agent that (fig.
Page 15
Installation manual Triple M,L Smart Total Horizontal Length (THL): Elbows 45° or 30° vertical to horizontal THL is the Total Horizontal Length and plane: consists of elbows and pipes entirely in These are 30° or 45° elbows vertically the horizontal plane.
Page 19
Installation manual Triple M,L Smart 13 Calculation sheet Starter length (STL) First part on top of the appliance Value Flue length from 0,1m till 0,45m Flue length from 0,5m till 0,90m Flue length from 1m till 1,4m Flue length from 1,5m till 2m Flue length 2m or more Bend 90°...
Page 20
Installation manual Triple M,L Smart found value Search in the table at TVH and THL and enter the value that is found. ……………………………… If the detected value is a number, check whether the completed STL is higher or equal to the value in the table.
Page 21
Installation manual Triple M,L Smart Technical data 14.1 Triple M Smart Technical data Type indication(s) Triple Smart M, Duet Smart M, Concept III Type appliance C11/C31/C91 Diameter outlet/inlet 100/150 Gas connection 3/8" Indirect heating functionality Category II2H3+ Symbol Unit Reference gas/inlet pressure...
Page 22
Installation manual Triple M,L Smart 14.2 Triple L Smart Technical data Type indication(s) Triple Smart L Type appliance C11/C31/C91 Diameter outlet/inlet 100/150 Gas connection 3/8" Indirect heating functionality Category II2H3+ Symbol Unit Reference gas/inlet pressure G20-20 G30-30 G31-37 mbar Emissions in space heating mg/kWh (GVC) input...
Page 23
Installation manual Triple M,L Smart Outlet position Please note! These rules apply only for the proper functioning of the unit, for ventilation and environmental protection you need to comply with the applicable rules as defined in the building regulations. Short roof terminal.