GE IC3645SR4R333AS2 Installation And Operation Manual page 19

Separately excited (sx) transistorized dual motor traction controllers
Table of Contents

Advertisement

DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Accelerator input voltage too low on
-08
power up after initial key switch
closure.
MEMORY R CALL
E
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Accelerator input mis-adjusted or defective.
Traction
· Input voltage at P7 should be more than 3.0
Controller
volts. Adjust or replace accelerator unit to
insure that the voltage at P7 is more than 3.0
volts before depressing pedal.
Short circuit between battery negative and P7 in
accelerator input circuit.
· Disconnect wire from P7. Check for short
circuit from wire to battery negative.
Resistance should be greater than 4.7K ohms.
Defective control.
· Disconnect wire from P7. Measure voltage
from P7 to negative. Voltage should be greater
than 4.5 volts, if not, replace control.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
The travel enable switch is open and
-09
the directional switch is closed.
MEMORY R CALL
E
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Directional switch welded closed or mis-adjusted
Traction
to be held closed.
Controller
· Replace or adjust directional switch to insure
that it opens when directional switch is
returned to neutral.
Short circuit between battery positive and P4.
· Disconnect wire from P4 and check wire for
short circuit to positive side of directional
switch.
Defective Control
· Disconnect wires and measure voltage at P4.
Voltage should be less than 60% of battery
volts.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when the
accelerator input voltage at P7 is less than 3.0 volts,
and any of the following connections are opened and
closed: battery plug or key switch.
TROUBLE-SHOOTING DIAGRAM
P9 P7
P8
ACC POT
CAUSE OF STATUS INDICATION
This status code will be displayed when P5 is less
than 12% of battery volts and P4 is greater than 12%
of battery volts.
TROUBLE-SHOOTING DIAGRAM
KEY
SWITCH
L
P1
P17
P2
P6
Page 19
P7
P8
ACC POT
P3
P4
P5