Figure 4-7. Drive-Mounting Rails And Extensions Removal - Dell 2100 Service Manual

Dell poweredge 2100 servers: service manual
Hide thumbs Also See for 2100:
Table of Contents

Advertisement

4. If the drive is a SCSI drive, record the setting of the SCSI address
jumpers and SCSI bus termination jumper.
5. If present, remove the 50-pin to 68-pin adapter from the SCSI connec-
tor on the back of the drive.
Some drives use a 50-pin to 68-pin adapter between the SCSI cable and the
drive connector. Check the back of the drive for an adapter, if present,
remove it and retain it for use on the new drive.
drive-release
tabs

Figure 4-7. Drive-Mounting Rails and Extensions Removal

When you reinstall a SCSI drive, set the SCSI address jumpers and the SCSI
bus termination jumpers to the settings you recorded.
50- to 68-pin
drive-mounting rails (2)
adapter
drive-mounting
extensions
Removing and Replacing Parts