Invacare Action 5/MyOn HC User Manual page 23

Medium active wheelchair
Table of Contents

Advertisement

Standard height-adjustable foot plates:
1. Loose the fixing screw B with 5 mm Allen key.
2. Adjust the height and let the screw catch one of
the recesses on the foot plate tube.
3. Tighten the fixing screw B (3–5 Nm) in the desired
position.
The distance between the lowest part of the
footrest and the ground must be at least 50 mm.
Depth-, Angle- (1) and Width- (2) adjustable foot plates:
1. Loosen the fixing screw G or H with 5 mm Allen
key.
2. Adjust the depth and angle positions and firmly
tighten the fixing screw G (12 Nm) or H (8–9 Nm)
in the desired position.
1648855-D
Width-adjustable foot plates (2):
1. Loosen the two fixing screws I with 5 mm Allen
key.
2. Adjust the width position and firmly tighten the two
fixing screws I (3–5 Nm) in the desired position.
Invacare recommends that foot plate adjustment is carried
out by a qualified technician.
To ensure a good position of the feet, two types of
straps can be provided; the heel strap J (serial)
and the calf strap (optional) attached to the leg rest
support. Both adjustable by hook and loop fasteners.