Available languages

Problem
The compressor operates
continually.
There is too much frost
and ice.
The compressor does not
start immediately after
pressing the "FastFreeze"
or "FastCool", or after
changing the temperature.
Water flows on the rear
plate of the refrigerator.
Water flows inside the re‐
frigerator.
Water flows on the floor.
Possible cause
Temperature is set incor‐
rectly.
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The door is not closed
correctly.
The "FastFreeze func‐
tion" or "FastCool func‐
tion" is switched on.
The door is not closed
correctly or the gasket is
deformed/dirty.
The water drainage plug
is not correctly posi‐
tioned.
Temperature is set incor‐
rectly.
This is normal, no error
has occurred.
During the automatic de‐
frosting process, frost
melts on the rear plate.
Food products prevent
the water to flow into the
water collector.
The water outlet is clog‐
ged.
The melting water outlet
is not connected to the
evaporative tray above
the compressor.
ENGLISH
Solution
Refer to "Operation".
Wait few hours and then
check the temperature
again.
Refer to climate class chart
on the rating plate.
Allow food products to cool
to room temperature before
storing.
Refer to "Closing the door".
Refer to "FastFreeze func‐
tion" or "FastCool function".
Refer to "Closing the door".
Position the water drainage
plug in the correct way.
Refer to "Operation" .
The compressor starts after
a period of time.
This is correct.
Make sure that food prod‐
ucts do not touch the rear
plate.
Clean the water outlet.
Attach the melting water out‐
let to the evaporative tray.