Troubleshooting - Kobalt SGY-AIR176NB Use And Care Manual

Hvlp paint spray gun
Table of Contents

Advertisement

Available languages

Available languages

CARE AND MAINTENANCE
6. Screw on the Fluid Adjustment Knob (D)
clockwise.
Storage
1. When not using the spray gun, turn the fluid
adjustment knob counterclockwise (to open) which will reduce the spring
tension on the needle fluid tip.
2. Store the gun in a secure area and out of the reach of children.
When storing for longer than 1 week, add a couple drops of lubricant into
the air inlet.

TROUBLESHOOTING

If you have any questions regarding sprayer performance, please call our
Customer Service Department at 1-888-3KOBALT, 8:00 a.m. – 8:00 p.m.,
EST, Monday–Friday.
SPRAY PATTERN/PROBLEM POSSIBLE REASON
Improper spray pattern
Improper spray pattern
1)One side of air cap
is clogged.
2)Dirt on one side of
fluid nozzle.
1)Loose air cap/dirty
seal.
2)One side of air cap
is clogged.
3)Dried material on
one side of fluid
nozzle.
19
8
SOLUTION
Remove air cap and soak in
solvent, then blow air
through until clean. Wipe
off nozzle tip using a rag
moistened with thinner. To
clean holes, use a broom
straw or toothpick. Never try
to detach dried material with
a sharp tool.
1)Tighten air cap.
2)Remove air cap and soak
in solvent, then blow air
through until clean. Wipe
off fluid nozzle using a rag
moistened with thinner. To
clean holes, use a broom
straw or toothpick. Never
try to detach dried material
with a sharp tool.
Clockwise
D

Advertisement

Table of Contents
loading

This manual is also suitable for:

0192525