Environmental Specifications - Huawei FusionServer Pro 5885H V5 Technical White Paper

Table of Contents

Advertisement

Huawei FusionServer Pro 5885H V5 Server
Technical White Paper
Category
Security features

6.2 Environmental Specifications

Table 6-2 Environmental specifications
Category
Temperature
Relative humidity (RH,
non-condensing)
Air volume
Issue 09 (2020-06-05)
Specifications
● Power-on password
● Administrator password
● TCM (only in China)/TPM
● Secure boot
● Front bezel (optional)
Specifications
● Operating temperature: 5°C to 45°C (41°F to 113°F)
(ASHRAE Classes A2 to A4 compliant)
● Storage temperature (≤ 72 hours): –40°C to +65°C
(–40°F to +149°F)
● Long-term storage temperature (> 72 hours): 21°C
to 27°C (69.8°F to 80.6°F)
● Maximum temperature change rate: 20°C/h (36°F/h)
NOTE
The highest operating temperature varies depending on the
server configuration. For details, see
Limitations.
● Operating humidity: 8% to 90%
● Storage humidity (≤ 72 hours): 5% to 95%
● Long-term storage humidity (> 72 hours): 30% to
69%
● Maximum change rate: 20%/h
≥ 196 cubic feet per minute (CFM)
Copyright © Huawei Technologies Co., Ltd.
6 Product Specifications
Operating Temperature
54

Advertisement

Table of Contents
loading