Environmental Specifications - Huawei FusionServer Pro XH321 V5 Maintenance And Service Manual

Server node
Hide thumbs Also See for FusionServer Pro XH321 V5:
Table of Contents

Advertisement

FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide
Category
System management
Security features

3.2 Environmental Specifications

Table 3-2 Environmental specifications
Category
Temperature
Relative humidity (RH,
non-condensing)
Issue 17 (2021-03-09)
Specifications
● UEFI
● iBMC
● NC-SI
● Integration with third-party management systems
● Power-on password
● Administrator password
● TPM (only outside China)
● Secure boot
Specifications
● Operating temperature: 5°C to 35°C (41°F to 95°F)
(ASHRAE Class A2 compliant)
● Storage temperature (≤ 72 hours): –40°C to +65°C
(–40°F to +149°F)
● Long-term storage temperature (> 72 hours): 21°C
to 27°C (69.8°F to 80.6°F)
● Maximum rate of temperature change: 20°C (36°F)
per hour, 5°C (9°F) per 15 minutes
NOTE
● If a single fan is faulty:
● The highest operating temperature supported is 30°C
● If the power consumption of the processor is 125 W or
● When the server is configured with 6248R or 6258R
processors, the highest operating temperature is 30°C
(86°F).
● The highest operating temperature varies depending on
the server configuration. For details, see
Temperature
● Operating humidity: 8% to 90%
● Storage humidity (≤ 72 hours): 5% to 95%
● Long-term storage humidity (> 72 hours): 30% to
69%
● Maximum change rate: 20%/h
Copyright © Huawei Technologies Co., Ltd.
(86°F).
higher, the system performance may be affected or a
temperature alarm may be generated.
Limitations.
3 Product Specifications
A.2 Operating
27

Advertisement

Table of Contents
loading

Table of Contents