Environmental Specifications - Huawei FusionServer Pro XH628 V5 Server Node Technical White Paper

Table of Contents

Advertisement

Huawei FusionServer Pro XH628 V5 Server Node
Technical White Paper
Category
System management
Security features

6.2 Environmental Specifications

Table 6-2 Environmental specifications
Category
Temperature
Issue 05 (2020-09-03)
Specifications
● UEFI
● iBMC
● NC-SI
● Integration with third-party management systems
● Power-on password
● Administrator password
● TPM
● Secure boot
Specifications
● Operating temperature: 5°C to 40°C (41°F to 104°F)
(ASHRAE Classes A2 and A3 compliant)
● Storage temperature (≤ 72 hours): –40°C to +65°C
(–40°F to +149°F)
● Long-term storage temperature (> 72 hours): 21°C
to 27°C (69.8°F to 80.6°F)
● Maximum temperature change rate: 20°C/h (36°F/h)
NOTE
● If a single fan faulty, the highest operating temperature is
5°C (41°F) lower than the rated value.
● If the Intel
6150 or Platinum 8176, 8170) are used, the highest
operating temperature is 35°C (95°F).
● The operating temperature specifications vary depending
on the processors used:
● If the power of the processor is 165 W, the highest
● If the power of the processor is higher than or equal to
● If the power of the processor is lower than 150 W, the
● If the server is configured with XH628 V5 and V3 nodes,
the highest operating temperature is subject to the XH628
V5.
Copyright © Huawei Technologies Co., Ltd.
®
®
Xeon
Scalable processors (Gold 6144, 6146,
ambient temperature supported by the supercapacitor
is 33°C (91.4°F).
150 W and lower than 165 W, the highest ambient
temperature supported by the supercapacitor is 35°C
(95°F).
highest ambient temperature supported by the
supercapacitor is 40°C (104°F).