Combustion air slide valve

Operating lever for combustion air supply
● Operating lever on „0":
all slide valves closed
● Operating lever on „I":
Secondary air slide valve completely open /
Primary air slide valve completely closed
● Operating lever on „II":
Secondary air slide valve completely open /
Primary air slide valve completely open

Regulation of combustion air

Position of operating lever:
„II" ..... Ignition position, max. heat output
„I" ....... Nominal heat output with billet wood
„I" ....... Nominal heat output with wood briquettes
„0" ..... Obtain glow
● As the secondary air also contributes to the cleanliness
of the glass pane, the operating lever should be set on
"I" minimum. This also applies in the event of low-load
operation.
● When not operating the lever should be set on "0", to re-
duce the cooling down of the room.
26

Fire grate

Operating lever for the fire grate
● With the help of the operating lever the fire grate can
be opened or closed to move the ash from the combus-
tion chamber to the ash pan by pushing the fire grate
back and forth.
● Primary air can only enter the combustion chamber if
the fire grate is set on open position.