Combustion Air Slide Valve; Regulation Of Combustion Air - Olsberg Libra Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Combustion air slide valve

Operating lever for combustion air supply
● Operating lever on "0":
all slide valves closed
● Operating lever on "I":
Secondary air slide valve completely open /
Primary air slide valve completely closed
● Operating lever on "II":
Secondary air slide valve completely open /
Primary air slide valve completely open

Regulation of combustion air

Position of operating lever:
"II" .....................Ignition position, max. heat output
"I" .....................Nominal heat output with billet wood
"I" .....................Nominal heat output with wood briquettes
"0" ....................Obtain glow
● As the secondary air also contributes to the cleanliness
of the glass pane, the operating lever should be set on
"I" minimum. This also applies in the event of low-load
operation.
● When not operating the lever should be set on "0", to re-
duce the cooling down of the room.
14
Fire rust
Control lever for the fire rust
The control lever can be used to set up the grate and
move the ash out of the firebox by sliding the grate
back and forth into the ash box.
Primary air can only enter the firebox when the grate
is in the open position.
Wood storage
The wood storage below the combustion chamber is
equipped with a magnetic pressure lock. It can be opened
by lightly pressing the button. The closure is also done by
pressing lightly.
press here