Advertisement

Quick Links

BI-02B BI-04B BI-06B BI-08B BI-12B
BI-02B BI-04B BI-06B BI-08B BI-12B
Exported on  07/11/2019

Advertisement

Table of Contents
loading

Summary of Contents for BAS-IP BI-02B

  • Page 1 BI-02B BI-04B BI-06B BI-08B BI-12B BI-02B BI-04B BI-06B BI-08B BI-12B Exported on  07/11/2019...
  • Page 2: Table Of Contents

    Table of Contents Device description....................5 Appearance.............................5 Technical parameters..................6 Main features ..........................6 Functionality ..........................6 Configuration through WEB interface............7 Login ..............................7 Dashboard ............................8 Network information ..............................9 Network ............................9 Network settings................................9 Custom NTP .................................. 10 Management system ..............................10 Panel ..............................10 Apartment Settings..............................
  • Page 3 UKEY mobile access .........................39 Описание..................................39 Принцип работы ............................... 39 Мобильный доступ с приложением UKEYhttps://wiki.bas-ip.com/display/BASIPIDAPP/ UKEY....................................40 Настройка в три клика с приложением UKEY Cfghttps://wiki.bas-ip.com/display/ BASIPCONFIGID/UKEY+Cfg ..........................40 Способы получения мобильного идентификатора и карт доступа..........41 Recieving the RTSP stream from the panel's camera ..........46  –  3...
  • Page 4 • Device description (see page 5) • Technical parameters (see page 6) • Configuration through WEB interface (see page 7) • Installation and connection (see page 33) • Usage of the device (see page 39)  –  4...
  • Page 5: Device Description

    Device description The unique multi apartment outdoor panel has a stylish design. Calling panels BI-02B BI-04B BI-06B BI-08B BI-12B are available in gold, silver and black colors. They are equipped with a wide-angle camera and support BAS-IP UKEY mobile access.
  • Page 6: Technical Parameters

    Installation Type: Flush Keypad: Backlight piezo buttons Functionality Interface: Russian/English, WEB interface Opening the lock: From the monitor, by code, by card, from the BAS-IP Intercom application, UKEY Access control integration: WIEGAND-26+ output Shortcut buttons: Concierge button Number of call melodies: 4 polyphonic melodies, ability to customize melodies for different actions Authentication: Separate password for settings, WEB –...
  • Page 7: Configuration Through Web Interface

    Such access is provided to installation organizations to install and configure the system. Username: Select a user to change the password. Default values: The default administrator password is 123456. The default password for the manager is 1234. https://wiki.bas-ip.com/pages/viewpage.action?pageId=2753837 https://wiki.bas-ip.com/pages/viewpage.action?pageId=2753838 https://wiki.bas-ip.com/pages/viewpage.action?pageId=2753839 https://wiki.bas-ip.com/pages/viewpage.action?pageId=2753840 https://wiki.bas-ip.com/pages/viewpage.action?pageId=14058107 https://wiki.bas-ip.com/pages/viewpage.action?pageId=2753842...
  • Page 8: Dashboard

    Dashboard After successful authorization, the following interface will be displayed: Framework: Firmware version. Launcher: Launcher version. Hybrid Mode: The current connection mode of the hybrid adapter. Hybrid Version: Hybrid adapter version. Serial number: Serial number of the device. Device name: Name of the device. Configuration through WEB interface – ...
  • Page 9: Network Information

    Network information DHCP: The current state of the DHCP connection. IP Address: The current IP address of the panel. Subnet Mask: Subnet Mask. Gateway Address: The address of the main gateway. DNS server: DNS server address. MAC address: MAC address of the panel. Network Network settings DHCP: Enable/disable mode to get network settings automatically. ...
  • Page 10: Custom Ntp

    DNS: DNS server address. Custom NTP NTP: Enable/disable the use of a custom NTP server. URL: The input field for the user NTP server address. Time Zone: Select the time zone. Management system Mode: Selects the operation mode of the panel control system. URL: Management server address.
  • Page 11: Sip Settings

    Information about operation modes If you select the "Wall" mode, you must enter 4 digits of the building number, 2 digits of the unit number, 2 digits of the floor number, and 2 digits of the apartment number to call the desired monitor.  If you select the "Unit"...
  • Page 12: Call Settings

    Example: stun.l.google.com. STUN port: The port of the STUN server. Example: For google STUN server 19302 port is used. Password: Password of SIP number. Call settings Concierge: Enable / disable the function to call the specified number in the "Number" line when pressing the concierge button.
  • Page 13: Apartments

    This menu displays a list of apartments. An apartment is a logical entity intended to bind identifiers, access codes and redirection rules. Use the address book: Enable/disable usage of address book to search and call the apartments from the main screen .  https://wiki.bas-ip.com/aa07v4/en/main-screen-2754641.html Configuration through WEB interface –  13...
  • Page 14: New Apartment

    New apartment After clicking on the "New apartment" button, the following interface will be displayed: Building: Building number 0001-9999 Unit:  Unit number: 00-99 Floor:  Floor number: 00-99 Apartment: Apartment number: 01-99 Apartment name: Apartment name. For example, "Smith's" Number of inhabitants: The conditional number of inhabitants who live in this apartment. After clicking on the "Confirm"...
  • Page 15: Acess Management

    The table contains the following columns: Apartment name: Apartment name. Number of inhabitants: The conditional number of inhabitants in this apartment. Number of identifiers: The number of identifiers that are issued for this apartment. Identifiers can be created in the "Access management" menu, tab "Identifiers". Number of access codes: The number of access codes issued for this apartment.
  • Page 16: Common Settings

    Common settings Master card: Master card number. Use master code: Enable/disable using master code to open the lock. Master code: The code entered on the keypad for opening the lock. When using the control module with two locks SH-42, when entering the master code on the panel, both locks will open.
  • Page 17: Open Lock

    Lock #1, Lock #2 Lock open time (s): Time for which the panel relay contacts are closed or open. Delay before opening: Time after which the contacts of the panel's relay will close or open. Open lock Lock #1, Lock #2 Open lock: The function of opening the selected lock from the panel WEB interface.
  • Page 18: Server Manage Access

    Server manage access Enabled: Turning on/off the panel operation mode, in which access cards and identifiers are not stored in the panel's memory and when placed to the reader, the panel will send a request to the server and wait for the answer - to give access or not. Use a custom server: Enable/disable the use of custom server to control the panel.
  • Page 19: Access Restrictions

    Apartment number: Select an apartment from the existing list of apartments. Name of the owner: Information about the owner of the identifier. Owner Type: Select the type of owner ID. The Owner and Guest types are available. Identifier Type: Select identifier Type. There are 3 types of identifiers available: Card - EM-Marin or Mifare card.
  • Page 20: New Restriction

    New restriction After clicking on the "New restriction" button, the following interface will appear: Name: The name of the rule. All day: Enable/disable the time restriction interval per day. Configuration through WEB interface –  20...
  • Page 21 If function is disabled, user can set time interval of this restriction. Start at - End at: Select the interval of action for this restriction. Repeat: Specify the duration of repetitions of this restriction. Configuration through WEB interface –  21...
  • Page 22 Duration of repetitions: Select the number of repetitions of this restriction. If you select the "Infinitely" option, rule will always act. If you select the "Until" option, you can set the end date for the action of this restriction. Configuration through WEB interface –  22...
  • Page 23: Forward

    Forward This section is used to substitute numbers by panel when making calls to internal monitors when there is no monitor or it is turned off, or to any given SIP number. Mode: Mode of the forwarding. All at once - the call is made to all numbers simultaneously.  One by one - the call is made to the numbers in turn with a delay of 20 seconds.
  • Page 24: The Numeration Order Of The Buttons On The Outdoor Panels

    Input format for SIP calls sip:5588@sip.bas-ip.com, where 5588 is the SIP number of the device being called, sip.bas-ip.com is the address of the SIP server, which can be specified either by the IP address or by the domain name. The numeration order of the buttons on the outdoor panels The numeration order on the outdoor panels is going from left to the right, from up to down: Configuration through WEB interface – ...
  • Page 25: Advanced

    Advanced This section is used to substitute the advanced settings of the panel. Configuration through WEB interface –  25...
  • Page 26: Announcement

    Announcement Enabled: Enable/disable displaying announcement (HTTP page or RTSP stream) in standby mode. URL: The URL of the displayed HTTP page or RTSP stream. Timeout: The timeout for advertising (10 - 300 minutes). RTSP Feed The function of viewing additional IP cameras during a call (up to 4 streams). This feature is available for v4 monitors and any other SIP devices with a keyboard.
  • Page 27: Custom Notifications

    During a call, it is possible to switch between streams by pressing keys from 1 to 5 in the monitor menu. The key "1" corresponds to the stream of the outdoor panel, the keys from "2" to "5" - to additionally added strams (transmission is carried out by DTMF RFC2833).
  • Page 28 Ring back: Sound and text message "Calling" when panel make an outgoing call. Door unlock: Sound and the text message "Welcome" when panel receive a signal to open the lock. Error:  Sound and text message "Error" when entering an unregistered subscriber number, the lock opening code and the presentation of an unregistered identifier. Configuration through WEB interface – ...
  • Page 29: Logs

    Emergency: Sound and text alert "Alarm!" when switching the panel to emergency mode. Switching occurs programmatically through BAS-IP Link or through third-party software using API. In emergency mode, locks connected to the panel are also opened. If any of the functions is turned off, the standard sound and the standard text message will be used.
  • Page 30: System

    Administrator - has full access to all panel settings. Manager - has access to the panel settings, but he has limited access to the access control menu. Typically, access to this account is provided to installers to install and configure the system.
  • Page 31: Settings

    Settings Choose file: Selecting the panel configuration file from the PC file system. Set default settings: Reset all panel settings to factory defaults. Backup all settings: Save and export configuration files. Device language Configuration through WEB interface –  31...
  • Page 32: Software Upgrade

    Select file: Select software update file from PC file system. After selecting the file, you must click on the "Update Software" button. Check for update: Check for software update on BAS-IP server or user server. Update software: Start software update.
  • Page 33: Installation And Connection

    Installation and connection This page describes the process of installation and connection of the outdoor panel. • Completeness check of the product (see page 33) • Electrical connection (see page 33) • Mechanical mounting (see page 37) • Connection of additional modules (see page 38) Completeness check of the product Before installation of the outdoor panel, it is necessary to check that it is complete and all...
  • Page 34 2. Connection scheme of electromagnetic lock using third-party power supply for the lock. Installation and connection –  34...
  • Page 35 3. Connection scheme of electromechanical lock using uninterruptible power supply UPS-DP-S.  Installation and connection –  35...
  • Page 36 3. Connection scheme of electromechanical lock using third party power supply for the lock. Installation and connection –  36...
  • Page 37: Mechanical Mounting

    Mechanical mounting Before installation of the outdoor panel it is necessary to provide a hole or a recess into a wall with dimensions 141×359×61 mm (for flush mount) dimensions of the bracket (mounting box) = 140×358×60 mm. It is also necessary to provide supply of a power cable, additional modules and the local network. ...
  • Page 38: Connection Of Additional Modules

    Installation height recommendations: The outdoor panel should be installed at a convenient height for you. Approximate height of installation is 160-165 cm of the camera level. Connection of additional modules The following modules can be connected to all multi apartment panels: •...
  • Page 39: Usage Of The Device

    (see page 46) UKEY mobile access Описание Мобильный доступ UKEY от BAS-IP является универсальной технологией для получения доступа в помещение или на территорию объекта с возможностью использовать в одном считывателе одновременно: карточки EM-Marin и MIFARE/шифрованные карты MIFARE Plus/MIFARE Classic, мобильный телефон (Bluetooth и NFC).
  • Page 40: Настройка В Три Клика С Приложением Ukey Cfghttps://Wiki.bas-Ip.com/Display/

    Мобильный доступ с приложением UKEY Для комфортной работы пользователей с вызывными панелями BAS-IP, оснащенными мультиформатными считывателями, компания BAS-IP выпустила новое мобильное приложение UKEY, которое после получения мобильного идентификатора используется для открытия дверей/ворот/шлагбаумов. Для каждой вызывной панели, оснащенной модулем считывателя с поддержкой мобильного...
  • Page 41: Способы Получения Мобильного Идентификатора И Карт Доступа

    привязывается только к одному мобильному устройству, что обеспечивает высокий уровень надежности и безопасности мобильных идентификаторов. Копирование и дублирование идентификатора невозможно. С помощью считывателя BAS-IP TR-03B Для того чтобы администратор управляющей компании мог с помощью TR-03B выдавать мобильные идентификаторы или записывать карты доступа, первоначально необходимо...
  • Page 42 6. Считыватель передаст мобильный идентификатор в ваш телефон и в приложении появится надпись "Ваш ключ готов"; Запись мобильных идентификаторов в ПО Management Software: 1. С помощью ПО "BAS-IP USB Reader Server" a. Скопировать  идентификатор из программы "BAS-IP USB Reader Server"; https://wiki.bas-ip.com/display/BASIPIDAPP/UKEY Usage of the device –  42...
  • Page 43 b. Внести в ПО "Management Software", на вкладку "Запись карт в базу", в строку внизу страницы и нажать кнопку "Добавить вручную"; c. Выбрать из списка справа необходимую панель; d. Нажать кнопку "Сохранить"; e. Перейти в вкладку "Активация карт"; Usage of the device –  43...
  • Page 44 f. Выбрать нужную панель; g. Нажать кнопку переноса данных в память панели; h. Нажать кнопку "Активировать"; i. Идентификатор внесен в базу и теперь вы можете пользоваться мобильным телефоном для открытия двери, ворот, шлагбаума. 2. Имея на руках QR-код  a. Открыть QR-код в любой программе для просмотра изображений; b.
  • Page 45 8. Поднести новую карту к считывателю, произведется запись шифрованного ключа в карту, после чего считыватель издаст звуковой сигнал; 9. Также ваш идентификатор карты отобразится в программе "BAS-IP USB Reader Server", его необходимо скопировать и внести в ПО "Management Software" для...
  • Page 46: Recieving The Rtsp Stream From The Panel's Camera

    4. Все идентификаторы карт отобразятся в программе "BAS-IP USB Reader Server", их необходимо скопировать и внести в ПО "Management Software" для требуемой вызывной панели; 5. Идентификаторы внесены в базу и теперь вы можете пользоваться картами для открытия двери, ворот, шлагбаума.

This manual is also suitable for:

Bi-04bBi-06bBi-08bBi-12b

Table of Contents