  • Page 2: Table Of Contents

    Table of Contents Device description....................5 Appearance.............................5 Technical parameters..................6 GENERAL CHARACTERISTICS....................6 FUNCTIONAL CAPABILITIES....................6 Configuration through WEB interface............8 Login ..............................8 Main ..............................8 Network info ...................................9 Network ............................10 Custom NTP .................................. 10 Device............................... 11 Apartment settings ..............................11 SIP settings..................................
  • Page 3 Usage of the device ................... 25 UKEY mobile access ......................... 25 Description ................................... 25 Working principle ..............................25 Mobile access with UKEY applicationhttps://wiki.bas-ip.com/basipidapp ........25 Triple-clicking setup with UKEY Cfghttps://wiki.bas-ip.com/display/BASIPCONFIGID/ UKEY+Cfg application ............................. 26 Ways to get mobile ID and access card ......................26 Recieving the RTSP stream from the panel's camera ..........
  • Page 4 • Device description (see page 5) • Technical parameters (see page 6) • Configuration through WEB interface (see page 8) • Installation and connection (see page 21) • Usage of the device (see page 25)  –  4...
  • Page 5: Device Description

    Device description BAS-IP AV-03D is a stylish panel that will surely fit perfectly into the interior of any office center. The panel is made of high quality plastic and can be used in almost any room. Appearance Device description –  5...
  • Page 6: Technical Parameters

    Installation Type: Surface FUNCTIONAL CAPABILITIES Interface: Russian / English, WEB - interface Opening the lock: From the monitor, from the BAS-IP Intercom application, via card, from the UKEY application Access Control AV-03ED: EM-Marin Contactless Card Reader Access Control AV-03MD: Mifare Contactless Card Reader...
  • Page 7 Optional: SIP P2P, Built-in Relay Technical parameters –  7...
  • Page 8: Configuration Through Web Interface

    Configuration through WEB interface • Login (see page 8) • Main (see page 8) • Network (see page 10) • Device (see page 11) • Access management (see page 13) • Forward (see page 17) • Advanced (see page 19) •...
  • Page 9: Network Info

    Device info Framework: A version of the framework. Launcher: A version of the launcher. Network info DHCP: Current DHCP status. IP адрес: Current IP address of the device. Subnet mask: Used subnet mask. Gateway: Gateway address. DNS server: DNS server address. MAC address: Physical address of the device. Configuration through WEB interface – ...
  • Page 10: Network

    Network DHCP: Enable/disable the automatic retrieval of network settings. IP: Panel IP address. By default, the call panel can have a static IP address 192.168.1.90 or 192.168.1.91. Mask: Subnet mask. Gateway: The main gateway. DNS: DNS server address. Custom NTP Current device date/time: Shows the current device's date and time.
  • Page 11: Device

    Device Apartment settings Mode: Panel's operation mode.  Building: Building number. Unit: Unit number. Flor: Floor number. Apartment: Apartment number. Device number: Device numeration number. Numeration of the panels If you have several call panels that have one logical address, then in the "No." field specify the value 2, 3, 4, 5, etc., up to 9. SIP settings Configuration through WEB interface – ...
  • Page 12: Call Settings

    Enable/Disable: Enable/disable SIP registration. Proxy: A proxy SIP server that can be represented by both an IP address and a domain name. Data format: Before the proxy address, you must specify "sip:". Server: SIP server address. Data format: Сan be represented by both an IP address and a domain name. STUN IP: STUN server address.
  • Page 13: Device Settings

    The maximum time for calling: The time interval after which the panel automatically ends an outgoing call if there is no answer. Maximum talk time: The time interval after which the panel automatically ends the outgoing conversation. Device settings Video quality: Select your preferred video resolution. RTP data profile: Select your preferred RTP data profile.
  • Page 14: Common Settings

    Common settings Master card: Master card number. Use master code: Enable/disable using master code to open the lock. Master code: The code entered on the keypad for opening the lock. When using the control module with two locks SH-42, when entering the master code on the panel, both locks will open.
  • Page 15: Open Lock

    Keep the lock open, if there is no SIP registration: Function to automatically open the lock if SIP registration on the panel is lost. No Sip registration time: Time period after which the lock begins to open if SIP registration on the panel is lost.
  • Page 16: New Identifier

    New identifier After clicking on the "New identifier" button, the following interface will appear: Identifier number: Number of identifier in decimal format. Building: building number 0001-9999 Unit:  Configuration through WEB interface –  16...
  • Page 17: Forward

    Unit number 00-99 Floor:  Floor number 00-99 Room: Room number 01-99 Forward This section is used to substitute numbers by means of the panel when making calls to internal monitors when there is no monitor or it is turned off, or to any given SIP number. Forward settings Mode: Mode of the forwarding.
  • Page 18 Input format for SIP calls sip:5588@sip.bas-ip.com, where 5588 is the SIP number of the device being called, sip.bas-ip.com is the address of the SIP server, which can be specified either by the IP address or by the domain name. Configuration through WEB interface –  18...
  • Page 19: Advanced

    Advanced RTSP feed: Function to view additional IP cameras during a call (up to 4 streams). This feature is available for v4 monitors and any other SIP devices with a keyboard. During a call, it is possible to switch between streams by pressing keys 1 through 5. The key "1"...
  • Page 20: Settings

    Settings Choose file: Selecting the panel configuration file from the PC file system. Set default settings: Reset all panel settings to factory defaults. Backup all settings: Save and export configuration files. Device language Choosing the language of the device. Reboot Reboot: Soft reset of the panel. Configuration through WEB interface – ...
  • Page 21: Installation And Connection

    Installation and connection This page describes the process of installing and connecting the call panel. • Completness check of the product (see page 21) • Electrical connection (see page 21) • Mechanical mounting (see page 23) • Connection of additional modules (see page 24) Completness check of the product Before installation of the outdoor panel, it is necessary to check that it is complete and all...
  • Page 22 2. Connection scheme of electromagnetic lock using external power supply for panel and the lock. Installation and connection –  22...
  • Page 23: Mechanical Mounting

    Mechanical mounting Before mounting the door panel, a hole or recess in the wall with dimensions of 20 × 50 × 60 mm (for flush mounting) must be provided. It is also necessary to provide for the supply of power cable, add. modules and local network. Installation and connection – ...
  • Page 24: Connection Of Additional Modules

    Connection of additional modules The following modules can be connected to the outdoor panel: • Module to control two locks SH-42 Installation and connection –  24...
  • Page 25: Usage Of The Device

    UKEY mobile access Description Ukey Mobile Access from BAS-IP is a universal technology for gaining access to the premises or to the territory of an object with the possibility to use in one reader simultaneously: EM-Marin cards and MIFARE/encrypted cards MIFARE Plus/MIFARE Classic, cell phone (Bluetooth and NFC).
  • Page 26: Ukey+Cfg Application

    For users' ease of operation with BAS-IP outdoor panels equipped with multi-format readers, the company BAS-IP has released a new mobile Ukey application which, after receiving the mobile ID, is used to open the doors/gates/parking gate arms.  For each outdoor panel equipped with a reader module with support for UKEY Mobile access, a different range of the mobile ID can be configured, in the range of 2 centimeters to 10 meters.
  • Page 27 You cannot copy or duplicate an identifier.  Using BAS-IP TR-03B reader In order for the administrator of the management company to be able to use TR-03B to issue mobile identifiers or to record access cards, it is necessary to specify the master-card, ...
  • Page 28 5. Bring a cell phone to the reader (make sure Bluetooth is on) and enter UKEY App, then press Obtain button or select Obtain BAS-IP TR-03 key.  6. The reader will transmit a mobile ID to your cell phone, thus "Your key is ready" will appear in the app.
  • Page 29: Recieving The Rtsp Stream From The Panel's Camera

    Recieving the RTSP stream from the panel's camera To get the RTSP stream from the camera of the call panel to the video surveillance system, you need to put in the add line of the camera rtsp://admin:123456@192.168.1.16:8554/ch01, where admin is the login, 123456 is the password to access the WEB interface, 192.168.1.16 is the IP address of the panel, 8554 is the port of access to the camera, ch01 is the channel number.