Advertisement

BEST IDEAS FOR IP
INTERCOM SOLUTIONS

Advertisement

Table of Contents
loading

Summary of Contents for BAS-IP AV-01

  • Page 1 BEST IDEAS FOR IP INTERCOM SOLUTIONS...
  • Page 2 Note For the correct installation, follow the instructions. If you have any difficulty with installation and operation, please contact your dealer for advice. The technical parameters and specifications mentioned here may vary slightly from those stated in the instructions of the devices. This is our company conducts constant upgrading and improvement of the functionality to improve the characteristics of current devices.
  • Page 3: Table Of Contents

    CONTENT Individual outdoor panels Appearance ....................... Main functions ......................Technical parameters .................... Equipment ......................... Setting through WEB interface ................. Connection scheme ....................Mounting ........................Multi apartment outdoor panels Appearance ....................... Connection ........................ Equipment ......................... Setting through WEB interface ................. Connection scheme ....................Mounting ........................
  • Page 4: Appearance

    APPEARANCE Model AV-01 (v2.0 and v3.0 SIP) Model AV-01T (v2.0 and v3.0 SIP) LIGHT SENSOR LIGHT SENSOR MICROPHONE MICROPHONE CAMERA BACKLIGHT CAMERA BACKLIGHT READER FOR CONTACTLESS CARDS SIGN WITH THE SIGN WITH THE NUMBER NUMBER RING BUTTON RING BUTTON LOUDSPEAKER LOUDSPEAKER Model: AV-02 v3.0 SIP...
  • Page 5: Main Functions

    MAIN FUNCTIONS Interface Authentication WEB-interface WEB-interface Lock opening Talking mode By card, with the monitor Double-sided Access control Talking time Reader for contactless cards Up to 240 seconds EM-Marin or MIFARE Additional functions Integration with ACS SIP P2P Output WIEGAND-26 Place for the signature near the call button Buttons for quick dialing...
  • Page 6: Equipment

    «Upgrade Tool» to determine the IP-address of the outdoor panel. Press the “Search” button and the program window will display the IP-address of the outdoor panel and any other devices BAS-IP, which are connected to the local network.
  • Page 7 SETTING THROUGH WEB INTERFACE To configure the outdoor panel through the WEB-interface, you must connect to it sing a web browser on a PC. The panel must be connected to the same local network segment as the PC from which you plan to make the settings.
  • Page 8 SETTING THROUGH WEB INTERFACE BuildNo: Specify the house number. UnitNo: Specify the entrance number. Floor: Specify the number of the floor. RoomNo: Specify the number of the apartment. No: Specify the outdoor panel serial number. Panel mode: Set the operating mode «Personal Panel». The number of the building, entrance, floor, and apartment must match the address of the internal monitor, which will receive a call from this outdoor panel.
  • Page 9 SETTING THROUGH WEB INTERFACE Proxy: SIP-server address. It can be specified as the IP address and the domain name. For example: sip: 192.168.1.99, or sip: sip.linphone.org. Domain: The domain address of the SIP-server is often the same as the IP address of the SIP-server.
  • Page 10 SETTING THROUGH WEB INTERFACE Getting streaming video via RTSP: To display streaming video to the network recorder (NVR) or display it in the video player, for example, VLC Media Player, it is necessary to address the outdoor panel using the following initialization string: rtsp://address:8554/ch01, where the address –...
  • Page 11: Connection Scheme

    CONNECTION SCHEME Connection by an external power supply (AV-01 and AV-01T) NETWORK SWITCH ONLY Black Data 1 Data 0 Yellow “EXIT“ BUTTON CAT 5e OUTDOOR PANEL +12 V LOCK POWER SUPPLY Connection by an uninterruptible power supply (AV-01 and AV-01T)
  • Page 12 CONNECTION SCHEME Connection by an uninterruptible power supply (AV-01 and AV-01T) NETWORK SWITCH ONLY Black Data 1 Data 0 Yellow “EXIT“ BUTTON CAT 5e OUTDOOR PANEL +12 V CTRL LOCK 1 LOCK LOCK 2 UPS DP/P NETWORK SWITCH CAT 5e...
  • Page 13 CONNECTION SCHEME Connection by an uninterruptible power supply (AV-01 and AV-01T) NETWORK SWITCH CAT 5e 485- 485- 485+ 485+ OUTDOOR PANEL LOCK +12 V POWER SUPPLY ATTENTION: SGND THE LOCK OPENING TIME CTRL Lock IS SET BY ADJUSTING THE Lock...
  • Page 14: Mounting

    MOUNTING MODEL SOCKET WATER- WIRES PROOF COM- PACTORS OUTDOOR PANEL THE HOLES FOR THE SCREWS SCREWS NICHE GUTTER PLATE WITH THE NUMBER BRACKET HOLE FOR WATER RUNOFF. PLEASE DO PROTECTIVE NOT COVER DURING COVER MOUNTING.
  • Page 15 MOUNTING THE HOLES FOR THE SCREWS SCREWS GUTTER BRACKET HOLE FOR WATER RUNOFF. PLEASE DO NOT COVER DURING MOUNTING.
  • Page 16: Multi Apartment Outdoor Panels Appearance

    APPEARANCE Model: BA-04 v3.0SIP Backlight Camera Loudspeaker Call button Microphone Apartment number Light sensor Concierge button Reader for contactless cards and keys Model: BA-08 v3.0 SIP Backlight Camera Loudspeaker Call button Microphone Apartment number Light sensor Concierge button Reader for contactless cards and keys...
  • Page 17: Connection

    SPECIFICATIONS Panel type Protection class Individual IP65 Screen Operating temperature -40 – +65 С Camera Power consumption 1/3”, adjustment of the camera direction 5,5 W, in standby – 2,5 W Angle Power + 12 V 71° horizontal × 56° vertical Body Resolution Metal...
  • Page 18: Setting Through Web Interface

    SETTING THROUGH WEB INTERFACE To configure the outdoor panel through the WEB-interface, you must connect to it with a web browser on a PC. The panel must be connected to the same local network segment as the PC from which you plan to make the settings. In the Internet browser in the address bar, enter the IP-address of the outdoor panel, and then enter the username and password.
  • Page 19 SETTING THROUGH WEB INTERFACE 2. Device Settings. Select «Device» to access the configuration of the logical address, the operating mode and ringtones: BuildNo: Specify the house number. UnitNo: Specify the entrance number. Floor: Specify the number of the floor. RoomNo: Specify the number of the apartment. No: Specify the outdoor panel serial number.
  • Page 20 SETTING THROUGH WEB INTERFACE 3. Access Settings. Select «Access» to setting the opening time and the delay time of delay forthe opening the door: Registration for contactless cards via WEB-interface. Enter in the “Master-card” number 0, and then click «Apply». Within 20 seconds, bring the required fregistration master card to the area of the outdoor panel’s reader –...
  • Page 21 SETTING THROUGH WEB INTERFACE Proxy: SIP-server address can be specified as both the IP address and the domain name. For example: sip: 192.168.1.99, or sip: sip.linphone.org. Domain: the domain address of the SIP-server is often the same as the IP address of the SIP-server.
  • Page 22 SETTING THROUGH WEB INTERFACE The numbers of call buttons look as follows: 0001 0005 0002 0006 0001 0003 0003 0007 0002 0004 0004 0008 Also, this section may be used for forwarding calls made by the SIP protocol when there is no internal monitor, on any given SIP-account (SIP-number). 1.
  • Page 23 SETTING THROUGH WEB INTERFACE 6. External Module settings (optional). Select «ExModule» to go to the following interface: The address of the external VOIP-converter is set, which is transforms the SIP protocol in the PSTN (Public Switched Telephone Network). 7. Advanced settings. Select “Advanced”...
  • Page 24 SETTING THROUGH WEB INTERFACE 8. Sign Out. Select «Sign Out» to enter the next interface: Click «Apply» button to exit the WEB-interface of the outdoor panel. Getting streaming video via RTSP: To get display streaming video to the network recorder (NVR) or display it in the video player, for example, VLC Media Player, enter the address the outdoor panel using the following initialization string: rtsp://address:8554/ch01, where address –...
  • Page 25: Connection Scheme

    CONNECTION SCHEME Connection using an external power supply. For connecting high power electric locks, you must use an additional power sup- ply. The BA-04 and BA-08 connection diagram from the included power supply, with an electromechanical lock is presented below: Network switch BLACK YELLOW...
  • Page 26 CONNECTION SCHEME Connection using an external power supply. For connecting high power electric locks, you must use an additional power sup- ply. The BA-04 and BA-08 connection diagram from the included power supply, with an electromechanical lock is presented below: Network switch “EXIT“...
  • Page 27 CONNECTION SCHEME Connection by a Uninterruptible Power Supply (UPS). For connecting high power electric locks you must use an additional power supply. The BA- 04 and BA-08 connection diagram from the uninterruptible power supply, with an electromechanical or electromagnetic lock is presented below: Network switch BLACK...
  • Page 28: Mounting

    MOUNTING Model: BA-04/08 v3.0 SIP Wall mounting Dimensions of the bracket = 142 × 245 × 55 мм Outdoor panel Screws Attention: Bracket The hole in the bottom of the bracket is designed to drain off water, do not cover it. It is also necessary to put the discharge gutter at the bottom of the niche,...
  • Page 29: Internal Monitors Appearance

    APPEARANCE Multi apartment outdoor panels BACKLIGHT BACKLIGHT LOUDSPEAKER LOUDSPEAKER CAMERA CAMERA LCD DISPLAY BUTTONS BUTTONS LIGHT SENSOR LIGHT SENSOR MICROPHONE MICROPHONE READER FOR READER FOR CONTACTLESS CONTACTLESS CARDS AND KEYS CARDS AND KEYS CAMERA BACKLIGHT LOUDSPEAKER LCD DISPLAY BUTTONS MICROPHONE READER FOR CONTACTLESS CARDS AND KEYS...
  • Page 30: Main Functions

    MAIN FUNCTIONS 1. The bright backlight of buttons and backlights for video cameras. 2. Graphic LCD display with backlight and support for the Rrussian language. 3. Color camera with night mode function. 4. Making calls to internal monitors, centralized remote concierge. 5.
  • Page 31: Setting Through Web Interface

    SETTING THROUGH WEB INTERFACE To configure the outdoor panel through the WEB-interface, you must connect to it with a web browser on a PC. The panel must be connected to the same local network segment as the PC from which you plan to make the settings. In the Internet browser in the address bar, enter the IP-address of the outdoor panel, and then enter the username and password.
  • Page 32 SETTING THROUGH WEB INTERFACE BuildNo: Specify the house number. UnitNo: Specify the entrance number. Floor: Specify the number of the floor. RoomNo: Specify the number of the apartment. No: Specify the outdoor panel serial number. Panel mode: Set the operating mode «Unit Panel». The number of the building, entrance, floor, and apartment must match the address of the internal monitor, which will receive a call from this outdoor panel.
  • Page 33 SETTING THROUGH WEB INTERFACE 4. SIP settings. Select «VOIP» for the transition to SIP account settings: Proxy: SIP-server address can be specified as both the IP address and the do- main name. For example: sip: 192.168.1.99, or sip: sip.linphone.org. Domain: domain address of SIP-server is often the same as the IP address of the SIP-server.
  • Page 34 SETTING THROUGH WEB INTERFACE This section is used to forward calls received at the internal monitors when the monitor is not available or it has been disabled on any given SIP-account (SIP-num- ber). Apartment: enter the number of the apartment after calling on which the call for- warding will occur.
  • Page 35 SETTING THROUGH WEB INTERFACE In the settings of the device on which the call is coming, you must create a SIP-account in where you specify the IP address of the outdoor panel as the SIP server address, the desired display number from the preceding paragraph as a login and leave the password field empty.
  • Page 36 SETTING THROUGH WEB INTERFACE 7. Advanced settings. Select “Advanced” to enter the following interface: Advertisement: set the advertising that will be displayed on the outdoor panel screen when the panel goes into standby mode. Time: set the time after which the advertising will begin to display. Address: specify the address of the page with ads for standby mode.
  • Page 37 SETTING THROUGH WEB INTERFACE 8. Sign Out. Select «Sign Out» to enter the next interface: Click the «Apply» button to exit the WEB-interface of the outdoor panel. Getting streaming video via RTSP: To display streaming video to the network recorder (NVR) or display it in the video player, for example, VLC Media Player, enter the address of the outdoor panel using the following initialization string: rtsp://address:8554/ch01, where the address –...
  • Page 38: Connection Scheme

    CONNECTION SCHEME UPS - DP/P Door Exit contact button LOCK RJ45 1 2 3 4 Wiegand 26 Yellow Data 0 Data 1 Black Attention: 1. The lock opening time is set by adjusting the resistor on uninterruptible power supply board UPS –...
  • Page 39: Installation

    INSTALLATION : AA-01 odel All Mounting 39 × × iMensions of the brAcket utdoor pAnel iche The hole in the bottom of the bracket is designed to drain off water, do not cover it. It is also necessary to make the discharge gutter at the bottom of the niche, which will be used to drain...
  • Page 40: Appearance

    APPEARANCE Internal monitors Speakerphone Power indicator Photo frame Message indicator Concierge Security indicator View Alarm indicator Open...
  • Page 41: Main Functions

    MAIN FUNCTIONS 1. Touch screen made by SpeedRight technology. 2. Intuitive interface for management and configuration. Changeable wallpapers, passwords for the user and installer, additional settings via the WEB-interface. 3. Video intercom between the internal monitors. 4. Support of 8 loops of home alarm, which can be connected to any security sensors with NO or NC contacts.
  • Page 42: Configuration Via The Monitor'sgraphic Interface

    CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE Main screen: Sequrity, VOIP, Smart, Service, Contacts, Media Player. Status icons: Service, the SIP status, Voice recorder, Security, Mute. The functionality of status icons: 1. Services: Order of services, access to the specified WEB-page, receiving news. Messages and status of the local network.
  • Page 43 CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 1. Security. Depending on the model of the internal monitor, can be from 4 to 8 loops security alarm. Click the “Security” to enter the interface: Alarms can be set in different modes: “Home”, “Out” and “Sleep”. 1.1 Switching security modes.
  • Page 44 CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 2. IP-cameras. Click the “Camera IP» button to enter the viewing interface IP-based cameras: Press the “Right” or “Left” button to select the desired camera. Then, press the camera button to view it and pause button to stop. 3.
  • Page 45 CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 3.1 Wieving outdoor panels. Push the “Monitor“ button to go to the following interfase. By clicking on the word “Door01“ you can switch between personal panel and milti-apartment panel. Use the “Right” and “Left” buttons to choose the number of multi-apartment and individual panels.To view the selected panel, press the button “Watch”, and to complete - the button “Pause”.
  • Page 46 CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 3.2.2 Intercom. The system supports the function of the video intercom, through cameras that are built into the internal monitors. In order to transmit your image to another person, it is necessaryyou need to turn on a built-in camera. Answering machine: When the outdoor panel’s call button is pressed, the monitor, in addition to automatic recording of images, can also record audio and video.
  • Page 47: Setting Through Web Interface

    SETTING THROUGH WEB INTERFACE 1. Network Settings. Select «Network» to access the network configuration settings: 2. Device Settings. Select «Device» to access the configuration of the logical address, the operating mode and ringtones.
  • Page 48 SETTING THROUGH WEB INTERFACE Building (House): specify the house number which must consist of numbers with values from 1 to 9999. Entrance: specify the entrance number which should be set within the range from 1 to 99. Floor: specify the floor number within the range of 0 to 99. Apartment: specify the apartment number within the range of 0 to 99.
  • Page 49 SETTING THROUGH WEB INTERFACE 7. Advanced settings. Select “Advanced” to enter the following interface: Forwarding: Enable or disable forwarding of incoming calls to a specified SIP-address (SIP-number). When this option is enabled, the internal monitor will simultaneously make a call to a given SIP-address when it receives any incoming call.
  • Page 50 SETTING THROUGH WEB INTERFACE The ONVIF string – should appear automatically as RTSP stream initialization string. If it does not appear, then the IP camera does not have a ONVIF, or its ONVIF specification does not meet the standards. In this case, the parameters must be filled manually, but you do not need to fill in the ONVIF field.
  • Page 51: Connection Scheme

    CONNECTION SCHEME V1+GND UTP CAT 5e +12VGND485+485- SH-61 Connection of the sockets on the back of the internal monitor.
  • Page 52: Appearance

    APPEARANCE Model AM-01 v3. Build-in camera (optionally) Handset Power indicator View button Door release button...
  • Page 53: Main Functions

    MAIN FUNCTIONS 1. Touch screen. 2. Photo and video recording of visitors. 3. The connection between the internal monitors and outdoor panels. 4. Viewing all authorized outdoor panels and lock control. TECHNICAL PARAMETERS 1. 9” TFT screen with touch control 2.
  • Page 54: Configuration Via The Monitor'sgraphic Interface

    CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE Main screen Communication: enter the calls menu View: enter the viewing outdoor panels menu. Call history: view the call history Applications: enter the additional functions menu Alarm records: view alarm messages System settings: access to the setup menu...
  • Page 55 CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 1. Network settings. IP addresses may not be identical withinin the same subnet. Network default: 255.255.255.000. Usually it is not necessary to change its values. To change the values of the required parameters, click, enter the required values, and click “Confirm”.
  • Page 56 CONFIGURATION VIA THE MONITOR’S GRAPHIC INTERFACE 2. The logical address settings. 1. In the “Building” field you must enter the logical adress of the concierge monitor. The IP-Address of the building must correspond to the building logical adress in the settings of the devices used. 2.
  • Page 57: Notes

    NOTES Technical maintenance of devices 1. Keep the devices clean and use a dry cloth for cleaning soft dust. 2. When cleaning the devices, please turn off the power. 3. If the device is very contaminated and cannot be cleaned with a dry cloth, please use a soft cloth dampened with diluted detergent, and then wipe it dry with a cloth.
  • Page 58 Terms of warranty 1. The warranty card must indicate the name of the model, serial number, purchase date, name of the seller, seal of the trade organization and the customer’s signature. Delivery to the warranty repair is the responsibility of the buyer.
  • Page 59 The warranty card number _______________ ________________________ The model name ________________________ Serial number ________________________ Full name of the seller With following stated terms of warranty is familiar, functional test was performed in my presence: Customer signature: _____________________________________________________ The warranty period of the product - 24 (twenty- four) months from the date of sale.

This manual is also suitable for:

Av-01tAv-02fpBa-08Aa-03Av-02Aa-05 ... Show all

Table of Contents