10.7

Maintenance

Maintenance comprises all measures for preserving the required condition.
Table 15: Maintenance measures
Measures
First oil change after start-up
Oil analyses
Subsequent oil changes
Clean the gear unit
Clean the air filter
Replacing the air filter cartridge
Checking tightness of the foundation
bolts
General inspection of the gear unit
Maintenance work on the oil-supply
system
Check couplings
Periods
after approx. 1000 operating hours
or depending on the results of the
oil analysis carried out
first one after 1000 operating
hours, all subsequent ones
annually
depending on the oil analysis
results; (without oil analysis: at the
latest after 18 months and/or
10000 operating hours)
as required, at least every 2 years
every 3 months
annually or when the air filter is
heavily soiled
every 12 weeks
every 2 years
See also operating instructions
oil-supply system.
every 6 months
BA 9142 en 02/2015
74 / 84
Remarks
See item 10.7.2
See item 10.7.1
See item 10.7.2
10.2
See item
.
10.3
See it.em
.
See item 10.3.1.
See item 10.7.3
See item 10.11
See also operating instructions
oil-supply system.
See operating instructions
individual components.