5
Fig. 10: Oil level, oil drain, and ventilating
1
Oil drain of the gear unit
2
Oil drain of tilting pad thrust bearing
3
Oil level of gear unit
Screw the screw plugs of the oil drain cocks (1, 2) back in.
Note
Check the condition of the sealing ring; the sealing ring is vulcanised onto the oil drain plug. If
necessary, use a new oil drain plug.
Information on the type, viscosity and required quantity of the oil is given on the rating plate on the gear unit
and/or in the documentation included in the delivery.
The BA 7300 instructions manual relating to the gear unit lubrication and Table "T 7300" containing the
current lubricant recommendations of Siemens can also be consulted on the internet (see back cover).
Note
For the oil filling of the gear unit, see the information in item 7.1.5.
In alternative to the oil change intervals indicated in Table 15 (see item 10.7), it is possible to have an oil
sample tested at regular intervals every 4 weeks by the technical service of the relevant oil company and
to have it released for further use.
If further usability has been confirmed, no oil change will be necessary.
Note
Observe the separately attached operating instructions BA 7300 and the information in item 7.1.
2
1
4
5
6
BA 9142 en 02/2015
77 / 84
6
4
3
Oil level of tilting pad thrust bearing
Air filter of gear unit
Air filter of tilting pad thrust bearing