Nibe ERS 10-500 Installer Manual

Nibe ERS 10-500 Installer Manual

Ventilation heat exchanger
Hide thumbs Also See for ERS 10-500:

Advertisement

Quick Links

Installer manual
NIBE™ ERS 10-500
Ventilation heat exchanger
IHB GB 1622-1
331802

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ERS 10-500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nibe ERS 10-500

  • Page 1 Installer manual NIBE™ ERS 10-500 Ventilation heat exchanger IHB GB 1622-1 331802...
  • Page 3: Table Of Contents

    6 Commissioning and adjusting Preparations Filling and venting Start-up and inspection 7 Program settings Start guide Menu system 8 Disturbances in comfort Info-menu Manage alarm Troubleshooting 9 Service Water seal for condensation water Heat exchanger NIBE™ ERS 10-500 Table of Contents |...
  • Page 4: Important Information

    Installer manual This installer manual must be left with the customer. Marking The CE marking means that NIBE ensures that the product meets all regulations that are placed on it based on relevant EU directives. The CE mark is obligatory for most products sold in the EU, regardless where they are made.
  • Page 5: Contact Information

    NIBE Energy Systems France Sarl, Zone industrielle RD 28, Rue du Pou du Ciel, 01600 Reyrieux Tel : 04 74 00 92 92 Fax : 04 74 00 42 00 E-mail: info@nibe.fr www.nibe.fr NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk...
  • Page 6: Delivery And Handling

    Installation area Leave free space of 800 mm in front of the product. NOTE Ensure that there is sufficient space (300 mm) above the exhaust air module for installing ventilation hoses. Chapter 2 | Delivery and handling NIBE™ ERS 10-500...
  • Page 7: Removing The Covers

    Front insulation The insulation in the front must be removed to access the internal parts. 1. Remove the air filter. 2. Slacken off the screws that hold the insulation in place. NIBE™ ERS 10-500 Chapter 2 | Delivery and handling...
  • Page 8: The Ventilation Heat Exchanger Design

    3 The ventilation heat exchanger design XL32 XL34 XL33 XL31 HQ11 HQ10 QN37 AZ30 EP26 XL40 Chapter 3 | The ventilation heat exchanger design NIBE™ ERS 10-500...
  • Page 9 HQ11 Air filter, supply air (Fine filter class F7) QN37 Bypass damper Miscellaneous Type plate Condensation water trough Designations in component locations according to standard IEC 81346-1 and 81346-2. NIBE™ ERS 10-500 Chapter 3 | The ventilation heat exchanger design...
  • Page 10: Pipe And Ventilation Connections

    100 mm must be guaranteed in the 2. Install ERS 10 on the brackets. water seal. 4 x Ø160 Chapter 4 | Pipe and ventilation connections NIBE™ ERS 10-500...
  • Page 11: General Ventilation Connections

    A defective ventilation installation may lead to reduced installation efficiency and thus poorer operating eco- nomy, and may result in moisture damage to the house. NIBE™ ERS 10-500 Chapter 4 | Pipe and ventilation connections...
  • Page 12: Electrical Connection

    A (vit) B (brown) B (brun) GND (green) GND (grön) NOTE If the supply cable is damaged, only NIBE, its service representative or similar authorised person may replace it to prevent any danger ERS 10 and damage. AA5-X4 A (white)
  • Page 13 The DIP switch (AA5-S2) must be set as follows. NIBE™ ERS 10-500 Chapter 5 | Electrical connection...
  • Page 14: Commissioning And Adjusting

    Order a ventilation adjustment to complete the setting. Ventilation capacity Tillgängligt Ventilationskapacitet Pressure tryck (Pa) (Pa) 100% Airflow (l/s) Luftflöde (l/s) Output, fans Effekt Power output Effekt 100% Airflow (l/s) Luftflöde (l/s) Chapter 6 | Commissioning and adjusting NIBE™ ERS 10-500...
  • Page 15: Program Settings

    (QN37) must open here. "Months btwn filter alarms": Set how often the filter alarm must be displayed. When ERS 10 is activated, the other ventilation menus will also light up. NIBE™ ERS 10-500 Chapter 7 | Program settings...
  • Page 16: Disturbances In Comfort

    External switch for changing the fan speed activated. ■ Check any external switches. – Silencers not correctly installed. ■ Check the silencers. – Chapter 8 | Disturbances in comfort NIBE™ ERS 10-500...
  • Page 17: Service

    Press gently from behind when removing the heat ex- changer. Bear in mind that the fins are sensitive and easily damaged. NOTE Do not damage the fins. If the fins are damaged the output may be reduced. NIBE™ ERS 10-500 Chapter 9 | Service...
  • Page 18: Accessories

    10 Accessories Electrical air heater EAH 10 This accessory heats the incoming outdoor air so that the extract air temperature is not too low. Part no. 067 567 Chapter 10 | Accessories NIBE™ ERS 10-500...
  • Page 19: Technical Data

    11 Technical data Dimensions Ø32 4 x Ø160 NIBE™ ERS 10-500 Chapter 11 | Technical data...
  • Page 20: Technical Specifications

    Length, supply cable Length, control cable Height Width Depth Weight Part no. 066 079 287 m /h at 50 Pa Temperature efficiency Temperaturhöjning förvärmningsbatteri ERS 10 Efficiency Temperatur (ºC) Airflow (m Luftflöde (l/s) Chapter 11 | Technical data NIBE™ ERS 10-500...
  • Page 21: Energy Labelling

    Information about supply/exhaust grilles in the facade See section General ventilation connections on page 11. Information about pre-/disassembly See section Recovery on page 4. This installer manual can also be accessed at www.nibe.eu. The annual electricity consumption kWh/year Annual heating saved, kWh primary energy per year...
  • Page 22: Electrical Circuit Diagram

    Electrical circuit diagram Chapter 11 | Technical data NIBE™ ERS 10-500...
  • Page 23: Index

    Contact information, 5 Marking, 4 Symbols, 4 Start-up and inspection Setting the ventilation, 14 Symbols, 4 The design of the exhaust air module, 8 List of components, 9 Troubleshooting, 16 Ventilation flow, 11 NIBE™ ERS 10-500 Chapter 12 | Item register...
  • Page 28 WS name: -Gemensamt WS version: a200 WS release date: 2016-06-03 11:12 Publish date: 2016-06-03 11:22 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 331802...