6 Commissioning and adjusting Preparations Filling and venting Start-up and inspection 7 Program settings Start guide Menu system 8 Disturbances in comfort Info-menu Manage alarm Troubleshooting 9 Service Water seal for condensation water Heat exchanger NIBE™ ERS 10-500 Table of Contents |...
Installer manual This installer manual must be left with the customer. Marking The CE marking means that NIBE ensures that the product meets all regulations that are placed on it based on relevant EU directives. The CE mark is obligatory for most products sold in the EU, regardless where they are made.
NIBE Energy Systems France Sarl, Zone industrielle RD 28, Rue du Pou du Ciel, 01600 Reyrieux Tel : 04 74 00 92 92 Fax : 04 74 00 42 00 E-mail: info@nibe.fr www.nibe.fr NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk...
Installation area Leave free space of 800 mm in front of the product. NOTE Ensure that there is sufficient space (300 mm) above the exhaust air module for installing ventilation hoses. Chapter 2 | Delivery and handling NIBE™ ERS 10-500...
Front insulation The insulation in the front must be removed to access the internal parts. 1. Remove the air filter. 2. Slacken off the screws that hold the insulation in place. NIBE™ ERS 10-500 Chapter 2 | Delivery and handling...
3 The ventilation heat exchanger design XL32 XL34 XL33 XL31 HQ11 HQ10 QN37 AZ30 EP26 XL40 Chapter 3 | The ventilation heat exchanger design NIBE™ ERS 10-500...
Page 9
HQ11 Air filter, supply air (Fine filter class F7) QN37 Bypass damper Miscellaneous Type plate Condensation water trough Designations in component locations according to standard IEC 81346-1 and 81346-2. NIBE™ ERS 10-500 Chapter 3 | The ventilation heat exchanger design...
100 mm must be guaranteed in the 2. Install ERS 10 on the brackets. water seal. 4 x Ø160 Chapter 4 | Pipe and ventilation connections NIBE™ ERS 10-500...
A defective ventilation installation may lead to reduced installation efficiency and thus poorer operating eco- nomy, and may result in moisture damage to the house. NIBE™ ERS 10-500 Chapter 4 | Pipe and ventilation connections...
A (vit) B (brown) B (brun) GND (green) GND (grön) NOTE If the supply cable is damaged, only NIBE, its service representative or similar authorised person may replace it to prevent any danger ERS 10 and damage. AA5-X4 A (white)
Page 13
The DIP switch (AA5-S2) must be set as follows. NIBE™ ERS 10-500 Chapter 5 | Electrical connection...
(QN37) must open here. "Months btwn filter alarms": Set how often the filter alarm must be displayed. When ERS 10 is activated, the other ventilation menus will also light up. NIBE™ ERS 10-500 Chapter 7 | Program settings...
External switch for changing the fan speed activated. ■ Check any external switches. – Silencers not correctly installed. ■ Check the silencers. – Chapter 8 | Disturbances in comfort NIBE™ ERS 10-500...
Press gently from behind when removing the heat ex- changer. Bear in mind that the fins are sensitive and easily damaged. NOTE Do not damage the fins. If the fins are damaged the output may be reduced. NIBE™ ERS 10-500 Chapter 9 | Service...
10 Accessories Electrical air heater EAH 10 This accessory heats the incoming outdoor air so that the extract air temperature is not too low. Part no. 067 567 Chapter 10 | Accessories NIBE™ ERS 10-500...
Length, supply cable Length, control cable Height Width Depth Weight Part no. 066 079 287 m /h at 50 Pa Temperature efficiency Temperaturhöjning förvärmningsbatteri ERS 10 Efficiency Temperatur (ºC) Airflow (m Luftflöde (l/s) Chapter 11 | Technical data NIBE™ ERS 10-500...
Information about supply/exhaust grilles in the facade See section General ventilation connections on page 11. Information about pre-/disassembly See section Recovery on page 4. This installer manual can also be accessed at www.nibe.eu. The annual electricity consumption kWh/year Annual heating saved, kWh primary energy per year...
Contact information, 5 Marking, 4 Symbols, 4 Start-up and inspection Setting the ventilation, 14 Symbols, 4 The design of the exhaust air module, 8 List of components, 9 Troubleshooting, 16 Ventilation flow, 11 NIBE™ ERS 10-500 Chapter 12 | Item register...