Download Print this page

Daikin FT24KV2S Service Manual page 21

Removal procedure, 5.0/6.0/7.1 kw class, 24000 btu/h class

Advertisement

Si041055
Step
Remove the fan motor.
3
Remove the fan rotor.
4
5
Remove the 2 screws
and remove the left side
plate.
The bearing is made of
6
rubber. Push it inward
and remove it.
Removal Procedure
Procedure
Fan rotor
Left side plate
Bearing
Removal of Fan Motor / Fan Rotor
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm of
play between the side face
of the rotor and the bottom
frame.
Fan motor
(R12897)
End of rotor
(1) Insert the fan motor with
approx. 5 mm left.
(R2809)
(2) Tighten the screw until it
stops. Then give the screw
one more turn.
(3) Rotate the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(5) If not appropriate, go back to
(1).
(R2810)
(R2811)
Points
End of
bottom frame
5 mm
(R2808)
(R9582)
19

Advertisement

loading