Removal of Electrical Box / PCBs / Swing Motors
Step
4. Remove the swing motor
for vertical blades.
Remove the swing shaft
1
on the right side.
2
Remove the 2 screws
and detach the swing
motor assembly.
Remove the 2 screws
3
and remove the swing
motor.
14
Procedure
Swing motor assembly
Hook
Hook
Some models have no swing
motor for vertical blades.
Remove the swing shaft.
(1) Unfasten the hook.
(2) Pull out the swing shaft.
(R2789)
(R2791)
The assembly has 6 hooks.
Swing motor
(R2792)
Si041055
Points
(R12896)