Download Print this page

Omron ZS-HLDS5 Instruction Sheet page 2

Sensor head for smart sensor

Advertisement

ZS-HLDS5/HLDS5T
Model
Sensor Head for Smart Sensor ZS-HLDC□□
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
■Export and Trade Control Laws
The  ZS-HLDS5  is  classed  as  a  commodity  (or  technology)  requiring 
acquisition  of  export  permission  in  accordance  with  foreign  exchange 
and  overseas  trade  control  laws.  When  the  ZS-HLDS5  is  to  be  taken 
outside of Japan, adopt the required procedures such as application for 
export permission by the Japanese government.
* Contact your OMRON representative.
TRACEABILITY INFORMATION:
Importer in EU :
Manufacturer:
Omron Europe B.V.
Omron Corporation,
Wegalaan 67-69
Shiokoji Horikawa, Shimogyo-ku,
2132 JD Hoofddorp,
Kyoto 600-8530 JAPAN
The Netherlands
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
© OMRON Corporation
2005
All Rights Reserved.
PRECAUTIONS ON SAFETY
●Meanings of Signal Words
Indicates  a  potentially  hazardous  situation  which,  if 
not  avoided,  will  result  in  minor  or  moderate  injury, 
WARNING
or may result in serious injury or death. Additionally, 
there may be significant property damage.
●Meaning of Alert Symbols
Indicates the possibility of laser radiation.
Indicates prohibition when there is a risk of minor 
injury from electrical shock or other source if the 
product is disassembled.
●Alert Statements in this Sheet
WARNING
Never look into the laser beam. 
Doing so continuously will result in visual impairment. 
Do not disassemble the product. 
Doing  so  may  cause  the  laser  beam  to  leak, 
resulting in the danger of visual impairment. 
PRECAUTIONS FOR SAFE USE
Please observe the following precautions for safe use of the product:
1. Do not use the product in environments where it can be exposed to
inflammable/explosive gas.
2. Do not disassemble, repair or modify this product.
3. Be sure to make sure that locking mechanisms are locked before use.
4. Dispose of this product as industrial waste.
PRECAUTIONS FOR CORRECT USE
1. Do not install the product in locations subjected to the following conditions:
・ Reflection of intense light (such as other laser beams or electric arc-welding
machines)
・ Presence of dust, oil droplets or spray on the filter on the front of the Sensor
Head
・ Presence of corrosive or flammable gases
・ Direct vibration or shock
2. Pre-installation Checks
・ The product cannot accurately measure the following types of objects:
(transparent objects, objects having an extremely low reflection factor, objects
smaller than the spot diameter, objects with a large curvature, excessively
inclined objects, etc.)
3. Wiring
・ Avoid wiring the cable between the Sensor Head and Sensor Controller
including this product near high voltage lines and power lines.
Wiring them together or placing them in the same duct may cause induction,
resulting in malfunction or damage.
・ Before connecting/disconnecting the Sensor Head, make sure that the Smart
Sensor is turned OFF. The Smart Sensor may break down if the Sensor Head is
connected or disconnected while the power is ON.
4. Cleaning
・ Do not use paint thinner, benzene, acetone or kerosene to clean the Sensor
Head. Doing so will melt the surface of the Sensor Head.
・ To remove dust particles, use a blower brush.
・ To remove stubborn dirt, wipe gently with a soft cloth moistened with a small
amount of alcohol.
5. Compatibility
・ The Sensor Head is compatible with the Sensor Controller, and can be used if
purchased separately.
LASER SAFETY
■Handling Precautions
・ The ZS-HLDS5/HLDS5T emits a visible laser beam. Do not stare directly into the laser.
Make sure that the laser beam path is terminated.
A non-reflective matte painted surface is ideal at the end of the laser beam path.
If specular objects are present in the laser beam path, make sure that they are prevented
from reflecting the laser beam. When used without an enclosure, make sure the laser
path from eye level is avoided.
■Specifications
Item
Model
Optical system
Diffuse reflection
Measuring center distance
Measuring range
Light source
Beam diameter (*1)
                        30×1000 μm
Linearity (*2)
Resolution (*3)
Temperature characteristic (*4)
                        ±0.01%F.S./℃
Sampling cycle (*5)
Lit near measuring center distance, and nearer than measuring center distance inside the measuring range
NEAR indicator
Blinks when the measurement target is outside of the measuring range or when the received light amount is insufficient
Indicators
Lit near measuring center distance, and further than measuring center distance inside the measuring range
FAR indicator
Blinks when the measurement target is outside of the measuring range or when the received light amount is insufficient
Operating ambient illumination
Ambient temperature
Ambient humidity
Degree of protection
Vibration resistance (destructive)
Shock resistance (destructive)
Materials
Cable length
Weight
Accessories
*1 Defined as 1/e
(13.5 %) of the center optical intensity in the measurement center distance (effective value). The beam diameter is sometimes influenced by the ambient conditions of the workpiece such as leaked light from the main beam.
2
*2 This is the error on the measured value with respect to an ideal straight line. In the diffuse reflection mode, the standard workpiece is white aluminumceramic, and is glass in the regular reflection mode. Linearity may change according to the
workpiece.
*3 This is the "peak-to-peak" displacement conversion value of the displacement output in the measuring center distance when the number of samples to average is set to 512, and the measuring mode is set to high-resolution mode. In diffuse reflection
mode, the standard workpiece is white aluminum ceramics, and glass in the regular reflection mode.
*4 This is the typical value obtained in the measuring center distance when the sensor and workpiece are fixed by an aluminum tool.
*5 This value is obtained when the measuring mode is set to the high speed mode.
Various safety standards regarding laser devices are stipulated depending on the
country of use.
The following describes the method of use according to where the product is exported.
(1) Using in U.S.
When using devices in which this product is installed in U.S., the devices are
subjected to the U.S. FDA (Food and Drug Administration) laser regulations.
Replace the warning label with the corresponding English
label (supplied with the sensor).
・ Place to affix the label
Laser Emission
Opening Label
Certification Label
CAUTION
PEAK POWER
1000
μw
PULSE DURATION
10000
μs
WAVE LENGTH
650
Class 2 Caution Label
(2) Using in a country other than U.S.
・ For countries other than Japan and U.S.,
warning labels must be replaced by English
ones (supplied with the product).
・ EN60825 is provided for products used in
Europe, and the content of this standard differs.
The ZS-HLDS5/HLDS5T is categorized as a
Class 2 device as stipulated in EN60825-1
(IEC60825-1).
ZS-HLDS5
Regular reflection
Diffuse reflection
50mm
44mm
50mm
±5mm
±4mm
±5mm
Visible semiconductor laser (wavelength 650 nm, 1mW max. , Class 2)
±0.1%F.S.
0.1μm
110μs
Illumination on received light surface 3000 lx or less (incandescent light)
Operating: 0 to +50℃, Storage: -15 to +60℃ (with no icing or condensation)
Operating and storage: 35% to 85% RH (with no condensation)
Cable length 0.5 m: IP66, cable length 2 m: IP67
10 to 150 Hz, 0.35-mm half amplitude 80 min each in X, Y, and Z directions
150m/s
2
3times each in six directions (up/down, left/right, toward/backward)
Case: aluminum die-cast, front cover: glass
0.5 m, 2 m
Approx. 600 g
Laser label (1 each for JIS/EN、 3 for FDA), Ferrite core (4 pcs), Insure Lock (2 pcs), Instruction Sheet
■Attaching the ferrite core
Attach three ferrite cores (provided with the Sensor Head) to the Sensor Head
side of the Sensor Head cable, and attach one ferrite core to the connector side
of the Sensor Head cable.
If the ferrite core comes loose from the cable, fasten the ferrite core in place with the
Insure Lock (supplied).
Ferrite core
■Dimensions
ZS-HLDS5/HLDS5T
22.7
LIGHTENING AXIS
CENTER
Dia. 13
RECEIVING AXIS
LIGHTENING PART
STANDARD SURFACE
3-Dia. 4.5 MOUNTING HOLES
RECEIVING PART
70±0.1
9.5±0.1
3-M4
MOUTING SCREW HOLES
ZS-HLDS5T
Regular reflection
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
44mm
Buyer's application or use of the Product. At Buyer's request, Omron will
provide applicable third party certification documents identifying ratings and
±4mm
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer's application, product or system.
Buyer shall take application responsibility in all cases.
0.25μm
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
OMRON Corporation
Tokyo, JAPAN
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
s
D
Oct , 2014
Insure Lock
Ferrite core
(unit: mm)
STANDARD SURFACE
AXIS
50
80
72
R2
OPERATING INDICATOR
4
70
5-R1
9.5
Dia. 21
8
R2
16.9
45.1
VINYL INSULATED ROUND CORD
Dia. 6.8 STANDARD LENGTH 2M
CONNECTOR
Suitability for Use
Industrial Automation Company
Contact: www.ia.omron.com

Advertisement

loading

This manual is also suitable for:

Zs-hlds5t