USER GUIDE
Cutout & Product Dimensions

PREPARE SITE

Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit
does not require additional air space for top, sides, or
rear. However, the front grille must NOT be obstructed,
and clearance is required for an electrical connection in
the rear.
CAUTION
!
Unit can NOT be installed behind a closed cabinet
door.
If you would like to align the face of the unit with
other adjacent cabinet doors, you may need to
alter the wall just behind the drain connection on
the unit to accommodate the drain.
CUTOUT DIMENSIONS
See Electrical
Specifications
for Power Supply
Preferred location
for water line and
eletrical outlet is in
adjacent cabinet.
32"
(813 mm)
to
33"
(178 mm)
(838 mm)
(102 mm)
*15" Cutout width sufficient if door protrudes beyond
adjacent cabinetry
PRODUCT DIMENSIONS
REAR
½
7
"
(191 mm)
Cutout & Product Dimensions
23-3/4"
(603 mm)
Minimum
5/8"
(16 mm)
7"
4"
15-1/4"
(387 mm)
3
"
Water Line
(80 mm)
Drain
½
7
"
(191 mm)
4"
4"
(102 mm)
(102 mm)
Power Cord
6 ft (183 cm)
2"
(51 mm)
FRONT
TOP
SIDE
8
u-line.com
14 ⁄ "
(379 mm)
28"
32" to 33"
(711 mm)
(813 mm to
838 mm)
3 ½"
(89 mm)
21 ⁄ "
(535 mm)
1 ⁄ "
(48 mm)
15 ½"
(394 mm)
22 ⁄ "
(576 mm)
24 ⁄ "
(624 mm)
10 ⁄ "
(259 mm)
4 ⁄ " (106 mm)

Hide quick links: