Water Hookup

PREPARE PLUMBING

The water valve uses a standard 1/4" (6.35 mm)
compression fitting. U-Line recommends using accessory
water hook up kit – part # 80-54674-00. The kit includes
a 10' (3 m) braided flexible water supply line and a brass
hose fitting.
CAUTION
!
Plumbing installation must observe all state
and local codes. All water and drain connections
MUST BE made by a licensed/qualified plumbing
contractor. Failure to follow recommendations
and instructions may result in damage and/or
harm.
Water Supply
When connecting the water supply, please note the
following:
Water Mineral Content:
TDS: greater than 5 ppm (mg/l) but less than
400 ppm (mg/l)
Hardness: Less than 200 mg/l (12 gpg)
Not recommended for use with softened water
A TDS meter is included with your unit
Water Treatment Options
TDS between 400-600 and/or hardness
between 13-20 can be treated by U-Line's in-line water
filter accessories available at u-line.com or your local
dealer:
 ULALINEFILTER — Standard
 ULALINEFILTERL — Large
 ULALINEFILTERHEAD — 3/8" NPT, initial
setup requires head & filter
Use bypass level 6
Water Quality
1-3 Users
400 TDS and/or 12
Optional
gpg hardness or less
Standard Filter
Change 1x per year
401-600 TDS and/or
Required
13-20 gpg hardness
Large Filter
Change 1x per year
601+ TDS, and/or
Contact your local water professional
21+ gpg hardness
Water Hookup
4+ Users
Optional
Large Filter
Change 1x per year
Required
Large Filter
Change 2x per year
10
The water pressure should be between 20 and 120 psi
(138 and 827 kPa).
The water line MUST have a shut-off valve in the
supply line.
The water line should be looped into 2 coils. This
will allow the unit to be removed for cleaning and
servicing. Make certain that the tubing is not pinched
or damaged during installation.
CAUTION
!
Do not use any plastic water supply line. The line
is under pressure at all times. Plastic may crack
or rupture with age and cause damage to your
home.
Do not use tape or joint compound when
attaching a braided flexible water supply line
that includes a rubber gasket. The gasket
provides an adequate seal – other materials
could cause blockage of the valve.
Failure to follow recommendations and
instructions may result in damage and/or harm,
flooding or void the product warranty.
Use new hose set. Do not reuse old hose set.
CAUTION
!
Turn off water supply and disconnect electrical
supply to unit prior to installation.
Use caution when handling back panel. The edges
could be sharp.
HOOKUP WATER
1.
Turn off water supply and disconnect electrical supply
to product prior to attempting installation.
2.
Remove the back panel.
u-line.com