In the case of an external Night Light application, plug
the 3 port connectors from the 12V Night Light.

WIRING

A relay is an electrically operated switch.
A Solid State relay is an electronic
switching device that switches states
when and external voltage is applied
along its junctions.
The Keen unit has a 12V output that can activate the
relay on or off. This function is triggered at every night
light button press or at the power button press. The
purpose of the Relay is to shut off power to the
ballast(s)/ driver(s) to emulate a true night light
function.
K1 (No relay)
1. Connect the DC power to the Keen unit
2. Do not connect the Violet and Grey wires
3. The unit should be on at full power, Connect the
Violet and Grey wires after the 12 Hour time
period.
K2/K3 (Relay)
1. Connect the DC Power to the Keen unit.
2. Connect the Red and Black wires to the Keen Unit.
3. Do not connect the Violet and Grey wires
4. The unit should be on at full power, Connect the
Violet and Grey wires after the 12 Hour time
period.
If you are using the Keen product in an LED
LIGHTING APPLICATION, there is no need to follow
these steps.
Keen™ Installation and Operation Manual

FLUORESCENT LAMP SEASONING

Seasoning fluorescent lamping helps to reduce
flickering and other lamp defects. We suggest (in
accordance to NEMA LSD-23-2010) leaving lamping at
full power for a minimum of 12 hours. Since the Keen
unit automatically dims to fewer than 50% after an
hour of no interaction, there is a special order of
operations to help season the lamping.