Light Bulb Replacement; Chain/Belt Tension - Genie 1035 Operation & Maintenance Manual

Hide thumbs Also See for 1035:
Table of Contents

Advertisement

F. Light Bulb Replacement
Use extreme caution when working from a ladder or step
stool or serious injury can occur.
When replacing light cover, make sure wires are not pinched
or near moving parts.
Use only properly rated incandescent, LED or CFL light bulbs.
DO NOT use bulbs with a rating greater than 60 Watts.
Use A19 size light bulbs. DO NOT use bulbs having a short
neck.
Changing Light Bulbs
1.
Disconnect power to door opener.
Open powerhead light cover(s) by pressing down on
upper locking tabs.
Replace old light bulb(s) with new.
Use 60 Watt MAX. incandescent bulbs or the CFL or LED
equivalent.
Close powerhead light cover(s).
2.
Reconnect power to door opener.
Test light operation.
NOTE: Use of LED bulbs may reduce the range of your remote
controls. Visit www.GenieCompany.com for more information
and recommendations for LED bulbs.
NOTE: SilentMax Connect™ models require a minimum 40
Watt or equivalent bulb, 60 watt maximum.
G. Chain/Belt Tension
If excessive chain/belt sag is noticed below the rail:
1.
Open the door until carriage is about mid travel and stop.
2.
Disengage the carriage and manually close the door.
3.
Loosen nuts on turnbuckle using 7/16" wrenches.
4.
Rotate turnbuckle counter-clockwise until slack is removed from
chain/belt.
5.
When measured on the opposite side of the rail from the
turnbuckle, a properly adjusted chain will have a 1/4" gap to the
bottom of the rail.
6.
Tighten nuts to secure turnbuckle.
7.
Be sure that chain/belt is not twisted or bound.
8.
Manually open door to re-engage carriage to turnbuckle.
14
MAINTENANCE & ADJUSTMENTS
WARNING
!
* Genie LED light bulbs are designed to reduce or
eliminate reduced remote range issues caused by
common LED bulbs. They also o er better product
life by making them resistant to vibration caused
by the opener, and cold or damp weather. See
website for details at www.GenieCompany.com.
AVERTISSEMENT
!
Faire particulièrement attention lors de travaux e ectués
depuis une échelle ou en escabeau.
En referment le couvercle de l'éclairage, s'assurer que les ls
ne sont ni coincés ni près des pièces mobiles.
Utilisez uniquement incandescence correctement classé, LED
ou des ampoules uocompactes.
NE PAS utiliser des ampoules avec une note supérieure à 60
Watts
Utilisez A19 ampoules de taille. NE PAS utiliser des ampoules
ayant un cou court.
1 Light Models
Push down tabs
Pull light cover away from powerhead
2 Light Models
Pull light covers away from powerhead
1/4"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents