Actuator Ces-A-Bqa - EUCHNER CES-A-UEA-02B Operating Instructions Manual

Non-contact safety system
Table of Contents

Advertisement

Operating instructions
Non-Contact Safety System CES-A-UEA-02B/CES-A-UEA-04B
11.9.

Actuator CES-A-BQA

Ì
Cube-shaped design 50 x 50 mm
Dimension drawing for CES-A-BQA
Technical data
Parameter
Housing material
Dimensions
Weight
Ambient temperature
Degree of protection
Installation orientation
Power supply
34
20,2
50
40
6
Active face
min.
Fortron, reinforced thermoplastic, fully encapsulated
-25
(Translation of the original operating instructions) 2097098-18-10/19
0
-
0,25
±0,15
Value
typ.
50 x 50 x 20.2
0.07
-
IP67
Active face opposite read head
Inductive via read head
Unit
max.
mm
kg
+70
°C