11.3.
Read head CES-A-LNA-...
Ì
Cube-shaped design 42 x 25 mm
Ì
Hard-wired cable
Dimension drawing
2 M4 x 14 safety screws included
Typical actuating range
With evaluation unit CES-A-UEA-.... and actuator CES-A-BBA
NOTICE
For a side approach direction for the actuator and read head, a minimum distance of s = 3 mm must
be maintained so that the actuating range of the side lobes is not entered.
Terminal assignment
Read head with connection cable
2097098-18-10/19 (Translation of the original operating instructions)
Non-Contact Safety System CES-A-UEA-02B/CES-A-UEA-04B
"l"
42
CES-A-L XXXXXX
32 ±0,1
Y
2 0
1 5
1 0
BN
Shield
WH
H11 H12 SH1
Evaluation unit
CES-A-UEA-...
12
4,6
Active face
5
5
1 0
1 5
2 0
Z
Read
head
Operating instructions
Approvals
Active face
23
EN