Read head CES-A-LCA-...

Ì
Cube-shaped design 42 x 25 mm
Ì
PE-HD plastic housing material, suitable for use in aggressive media (e.g. acids, alkalis)
Dimension drawing
NOTICE
The flat seal provided must be used during assembly.
Typical actuating range
With evaluation unit CES-A-UEA-.... and actuator CES-A-BCA
NOTICE
For a side approach direction for the actuator and read head, a minimum distance of s = 3 mm must
be maintained so that the actuating range of the side lobes is not entered.
Terminal assignment
Read head with connection cable
2097098-18-10/19 (Translation of the original operating instructions)
Non-Contact Safety System CES-A-UEA-02B/CES-A-UEA-04B
48
42
± 0,1
32
Flat seal
Active face
l
Y
2 0
1 5
1 0
5
5
1 0
1 5
BN
Shield
Read
head
WH
H11 H12 SH1
View on the plug
connector of the
Evaluation unit
read head
CES-A-UEA-...
Operating instructions
14
12
4,6
Active face
2 M4 x 14 safety screws included
2 0
Z
Approvals
EN