System Manual Safety System MGB-AR in Combination with a Locking Module Contents Correct Use Exclusion of Liability and Warranty General Safety Instructions Function System overview Locking module MGB-L1-AR-.../MGB-L-AR-... Handle module MGB-H-... Escape release MGB-E-... (optional) Dimension drawing Mechanical release Lockout mechanism Escape release (optional) Installation Changing Actuating Direction for Doors Hinged on the Left...
The safety system MGB can only be combined with the intended modules in the MGB system family. On the modification of system components, EUCHNER provides no warranty for safe function. Connection of several devices in a CES-AR switch chain is permitted only using devices intended for series connection with the CES-AR.
System Manual Safety System MGB-AR in Combination with a Locking Module Important! In the estimation of the PL for the overall system, a maximum value of 100 years can be assumed for the MTTF according to the limit value in EN ISO 1849-1:008, Section 4.5..
Prior to use read the operating instructions and the system manual, and keep these in a safe place. Ensure the operating instructions and the system manual are always available during mounting, setup and servicing. EUCHNER cannot provide any warranty in relation to the readability of the CD for the storage pe- riod required.
System Manual Safety System MGB-AR in Combination with a Locking Module System overview Locking module MGB-L1-AR-.../MGB-L2-AR-... Key: 1 Cover for mechanical release 2 LED indicator 3 Terminals X -X5 4 Locking arm 5 Auxiliary marking for maximum per- mitted mounting distance 6 Depending on version: Cable entry M0x1.5 or plug con- nector...
System Manual Safety System MGB-AR in Combination with a Locking Module Dimension drawing 16,5 73,5 CLOSED 15,4 OPEN 86,5 155,3 113,5 8 x 8 M20x1,5 (4x) 289,3 Figure 4: Dimension drawing, MGB fitted without optionial mounting plates...
System Manual Safety System MGB-AR in Combination with a Locking Module Mechanical release In the event of service, the guard locking can be released with the mechanical release irrespective of the state of the solenoid (see Figure 5). The locking screw must be screwed back in and sealed after use (for example with sealing lacquer).
System Manual Safety System MGB-AR in Combination with a Locking Module Lockout mechanism If the lockout bar is pivoted out, the bolt tongue cannot be extended. The lockout bar can be secured with padlocks (see Figure 6) To pivot out, press the grooved part (only possible with bolt tongue retracted). Key: 1 Padlock ∅...
Page 10
System Manual Safety System MGB-AR in Combination with a Locking Module Preparing the escape release Example with mounting plates: Actuation axis Protective sleeve Mounting plates 1 Fit door handle 2 Insert actuation axis. The locking ring A must be in contact with the escape release B.
System Manual Safety System MGB-AR in Combination with a Locking Module Installation Warning! Mounting must be performed only by authorized personnel. For installation steps see Figure 8 and Figure 9 to 14. Install system so that operation of the mechanical release as well as inspection and maintenance are possible.
System Manual Safety System MGB-AR in Combination with a Locking Module Changing Actuating Direction for Doors Hinged on the Left Important! It is only possible to make this change when the bolt tongue is not extended and an escape release is not yet mounted. As supplied, the handle module is set for doors hinged on the right.
System Manual Safety System MGB-AR in Combination with a Locking Module 3 mm CLOSED OPEN 9 Undo setscrew. AT Move door handle 90° clockwise and fasten again. Tighten setscrew to Nm AK State after the change Fig. 13: Changing actuating direction, step 9 and AT Figure 14: Changing actuating direction, final state Protection Against Environmental Effects Lasting and correct safety function requires that the system must be protected...
System Manual Safety System MGB-AR in Combination with a Locking Module Electrical Connection Warning! In case of an error, loss of the safety function through incorrect connection. To ensure safety, both safety outputs (OA and OB) must always be evaluated. ...
On the usage of other connection components, the requirements in the fol- lowing table apply. EUCHNER provides no warranty for safe function in case of failure to comply with these requirements. Observe the following requirements for the connection cables:...
System Manual Safety System MGB-AR in Combination with a Locking Module Notes on cable laying Lay all MGB connection cables in a common cable harness. MGB-L.-AR... + 24 V DC cabinet Important: lay cables in a common harness Figure 15: Stipulate cable laying...
System Manual Safety System MGB-AR in Combination with a Locking Module Pin assignment and contact description DIA 1 Power DIA 2 State Figure 16: Connections and LEDs Terminal Designation Description X.1 to X. See the enclosed data sheet X.4 Power supply for the interlocking solenoid and the monitoring out- puts, DC 4 V, must be present continuously so that the interlocking solenoid functions.
System Manual Safety System MGB-AR in Combination with a Locking Module Operation as separate device Figure 17: Connection example for separate operation The switches can be reset via the RST input. To do this, a voltage of 4 V is ap- plied to the RST input for at least seconds.
System Manual Safety System MGB-AR in Combination with a Locking Module Operation in a CES-AR switch chain Figure 18: Connection examples for operation in a CES-AR switch chain For detailed information on operation in a CES-AR switch chain, see the related CES-AR system manual.
System Manual Safety System MGB-AR in Combination with a Locking Module Information on operation in a CES-AR switch chain System times The locking module has longer response times than a CES-AR switch (see Technical data and diagram of Typical system times, Figure 0 and 1). Position in a CES-AR switch chain The locking module must be the last device in the CES-AR switch chain (see Figure 19).
System Manual Safety System MGB-AR in Combination with a Locking Module Setup Teach-in operation The handle module must be assigned to the locking module using a teach-in func- tion before the system forms a functional unit. During a teach-in operation, the safety outputs are in high-resistance state, i.e. the system is in the safe state.
Page 22
System Manual Safety System MGB-AR in Combination with a Locking Module Electrical function test Warning! On usage in a CES-AR safety chain, also follow the procedure for the function check in the related CES-AR system manual. Switch on operating voltage. ...
System Manual Safety System MGB-AR in Combination with a Locking Module Technical Data Note! If a product data sheet is included with the product, the information on the data sheet applies in case of discrepancies with the operating instructions. Parameter Value Unit Housing material...
System Manual Safety System MGB-AR in Combination with a Locking Module Typical system times Ready delay After switching on, the unit carries out a self-test for 8 s. The system is ready for operation only after this time. Risk time according to EN 60947-5-3 If the guard locking is no longer effective, the safety outputs OA and OB on the locking module are deactivated after a maximum of 00 ms.
System Manual Safety System MGB-AR in Combination with a Locking Module Troubleshooting Latching fault when actuating the escape release In order to achieve monitoring of the locking device in category 4, PL e according to EN ISO 1849-1, an internal monitoring logic system is integrated into every locking module.
System Manual Safety System MGB-AR in Combination with a Locking Module Inspection and Service Warning! Loss of the safety function because of damage to the device. In case of damage the related module must be replaced. The replacement of individual parts in a module is not permitted. Regular inspection of the following is necessary to ensure trouble-free long-term operation: ...
Need help?