Mindeo FS390 User Manual page 36

Fixed image scanner
Table of Contents

Advertisement

Example: Group 1  set 01 or 10, Group 2 and 4  set 24 or 42.
All valid settings include 00, 01, 02, 03, 04, 10, 11, 12, 13, 14, 20, 21, 22, 23, 24, 30, 31, 32, 33, 34, 40,
41, 42, 43, and 44.
Element amendment: If it is enabled, the scanner can read the barcode comprised with bars and
spaces in different scales.
Character output restraint:
Printable character only - If this option is selected, the scanner will output the printable characters only,
i.e. in ASCII from 20H to 7EH.
Alphanumeric character only - If this option is selected, the scanner will output the alphanumeric
characters only, i.e. "A"-"Z", "a"-"z", "0"-"9".
Decoder optimization: If it is enabled, the scanner will optimize the scanner with error correction. This
function is not effective for all types of barcode.
Character encoding system: A character encoding system consists of a code that pairs each character
from a given repertoire. Common examples include Morse code, the Baudot code, the ASCII and
Unicode. If the data received does not display with the proper characters (domestic language, e.g.
Chinese), it maybe because the barcode being scanned was created using a character encoding system
that is different from the one the host program is expecting. Try alternate options to find the proper one.
Idle optics module: If it is enabled, the power supply is removed from the optics module when the
scanner is in Idle/Standby/Sleep mode.
Operate time-out interval: While pin TRIG is pulled down or a decode command activates scanning,
the scanner enters Operate mode. The scanner will enter Idle mode from Operate mode if this interval
expires. In Operate mode, the scanner is capable of receiving commands via its serial port.
Standby mode enter: If this feature is enabled, the scanner can enter Standby mode.
Idle time-out interval: If the scanner is in Idle mode and Standby mode enter is enabled, the scanner
will enter Standby mode from Idle mode when this interval expires. If pin TRIG is asserted or a valid
command is received, Idle mode will terminate.
Sleep mode enter: If this feature is enabled, the scanner can enter Sleep mode.
Standby time-out interval: If the scanner is in Standby mode and Sleep mode enter is enabled, the
scanner will enter Sleep mode from Standby mode when this interval expires. If pin TRIG is asserted
or a valid command is received, Sleep mode will terminate.
Continue scan mode time-out: The longest time up to which the continue scan state stays on. This
feature is activated only when the Scan mode is in alternate or continuous mode. Once the continue
scan state ends, the scanner enters the Idle mode.