Mindeo FS390 User Manual page 18

Fixed image scanner
Table of Contents

Advertisement

The associated current draws of different power modes are listed in the following table.
Table 2-3 Current draws of different power modes @ 5V, 25°C
Power mode
Power-on I
Inrush
I
OperatePeak
Operate
I
OperateAverage
I
Idle, image on
Idle
I
Idle, image off
Standby
I
Standby
Infrared
I
Infrared
Note 1: While in Idle power mode, power can be removed from the optics module when Idle optics
module is enable, refer to
Maximum current spike seen when power is applied to
the scanner or when the scanner turns on for the first
time.
Peak current draw when the scanner is scanning.
Average current draw when the scanner is scanning.
Maximum current draw while not scanning or decoding,
but power is applied to the optics module.
Maximum current draw while power is NOT applied to the
optics module.
Maximum current draw while in Standby power mode.
Maximum current draw added while the infrared sensor is
active.
6-6 Scan mode & some global settings
Description
Note 1
.
10
Current
598 mA
432.5 mA
280 mA
85 mA
68.5 mA
45 mA
11 mA

Advertisement

Table of Contents
loading

Table of Contents