Axis P5624-E Mk II User Manual page 37

Ptz dome network camera
Table of Contents

Advertisement

AXIS P5624-E Mk II PTZ Dome Network Camera
Events
-
Day/Night Mode – Trigger the rule when the product switches between day mode (IR cut filter on) and night
mode (IR cut filter off). This can for example be used to control an external infrared (IR) light connected
to an output port.
-
Live Stream Accessed – Trigger the rule when any stream is accessed and during edge storage playback.
This can for example be used to send notifications.
-
Motion Detection – Trigger the rule when motion is detected. See Motion Detection on page 32.
-
Shock Detection – Trigger the rule when the Axis product detects it has been tilted or hit. See Shock Detection
on page 32.
Hardware
-
Network – Trigger the rule if network connection is lost or restored. This can for example be used to start
recording to the SD card.
-
Temperature – Trigger the rule if the temperature falls outside or inside the operating range of the product. This
can for example be used to send maintenance notifications.
Input Signal
-
Manual Trigger – Trigger the rule using the Manual Trigger button in the Live View page. See Controls on
the Live View Page on page 10. This can for example be used to validate actions during product installation
and configuration.
-
Virtual Inputs – can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, for
example, be connected to buttons in the VMS user interface.
PTZ
-
Error – Trigger the rule if the PTZ functionality is not working correctly. This can for example be used to
send maintenance notifications.
-
Moving – Trigger the rule when the camera view moves due to a PTZ operation. This can for example be used
as an additional condition to prevent an action rule triggered by motion detection to record video while the
camera view moves due to a PTZ operation.
-
Preset Reached – Trigger the rule when the camera stops at a preset position. This can be for example be used
with the Send Images action to upload images from the preset position.
-
Ready – Trigger the rule when the PTZ functionality is ready to be used. This can for example be used to steer
the camera to a specific preset position when the product is started.
Storage
-
Disruption – Trigger the rule if storage problems are detected, for example if the storage device is unavailable,
removed, full, locked or if other read or write problems occur. This can for example be used to send maintenance
notifications.
-
Recording – Triggers the rule when the Axis product records to the storage device. The recording status trigger
can be used to notify the operator, for example by flashing LED lights, if the product has started or stopped to
record to the storage device. Note that, this trigger can be used only for edge storage recording status.
System
-
System Ready – Trigger the rule when the product has been started and all services are running. This can for
example be used to send a notification when the product restarts.
Time
-
Recurrence – Trigger the rule periodically. See Set Up Recurrences on page 40. This can for example be used to
upload an image every 5 minutes.
-
Use Schedule – Trigger the rule according to the selected schedule. See Create Schedules on page 40.