Panasonic CS-YS9MKV-7 Service Manual page 76

Indoor unit outdoor unit
Hide thumbs Also See for CS-YS9MKV-7:
Table of Contents

Advertisement

14.4.16 F93 (Compressor Rotation Failure)
Malfunction Decision Conditions
A compressor rotation failure is detected by checking the compressor running condition through the position
detection circuit.
Malfunction Caused
Compressor terminal disconnect
Outdoor PCB malfunction
Troubleshooting
76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents