INSTALLATION MANUAL
FXMQ_PB/FBQ Economizer
MODELS
ECONMQ12P-8-1K
ECONMQ12P-13-1K
ECONMQ30P-8-1K
ECONMQ30P-13-1K
ECONMQ48P-8-1K
ECONMQ48P-13-1K
1

Advertisement

loading

Summary of Contents for Daikin ECONMQ12P-8-1K

  • Page 1 INSTALLATION MANUAL FXMQ_PB/FBQ Economizer MODELS ECONMQ12P-8-1K ECONMQ12P-13-1K ECONMQ30P-8-1K ECONMQ30P-13-1K ECONMQ48P-8-1K ECONMQ48P-13-1K...
  • Page 2 1. Ducted Indoor Unit Economizer Summary The Daikin economizer option allows the FXMQ_PBVJU indoor units to utilize outside air to reduce the mechanical cooling when the condition of the outside air permits. Automatic, sensor-controlled dampers provide a constant, programmable leaving air temperature from the economizer whenever the indoor unit receives a call for cooling and the outside air conditions satisfy enthalpy requirements.
  • Page 3 INSTALLATION MANUAL FXMQ_PB/FBQ ECONOMIZER 2. Dimensions Kit Model ECONMQ12P-8-1K 21.625 13.00 9.75 24.25 7.50 17.00 ECONMQ12P-13-1K ECONMQ30P-8-1K 36.4375 13.00 9.75 24.25 7.50 32.00 ECONMQ30P-13-1K ECONMQ48P-8-1K 52.1875 13.00 9.75 24.25 7.50 48.00 ECONMQ48P-13-1K...
  • Page 4: Installation

    INSTALLATION MANUAL FXMQ_PB/FBQ ECONOMIZER 3. Shipping and Packing List Economizer package contains: 1 ea. – Economizer Assembly 1 ea. – Install Instructions Including Wiring Diagram 3 ea. – Wire Ties 1 ea. – Honeywell JADE Operation Manual Installation Before starting the installation work, carefully read the following safety precautions. a) Disconnect all power to the indoor unit b) Remove the factory duct flange from the return inlet of the indoor unit.
  • Page 5: Wiring Diagram

    INSTALLATION MANUAL FXMQ_PB/FBQ ECONOMIZER C. Fan Mode 1. While in fan only operation, cooling thermo-off, and heating thermo-off, the damper will open to the minimum vent position. The minimum vent position is site-configurable. D. Enthalpy Control 1. The enthalpy economizer control senses both temperature and humidity of the outside air. When the heat content of the outside air is below the control set point, the control permits the outside air dampers to operate as described in section 5.A.2.
  • Page 6: System Setup

    INSTALLATION MANUAL FXMQ_PB/FBQ ECONOMIZER Fig. 3. Field Wiring Diagram 7. System Setup To use the keypad when working with Setpoints, System, and Advanced Settings, Checkout tests, and Alarms: • Navigate to the desired menu • Press the button (Enter) to display the first item in the currently displayed menu. •...