Page 1
Niky 600/800 Index 1 Introduction 2 Conditions of use 3 Installation 4 Signals and controls 5 Overload and self-shutdown 6 Features 7 Changing batteries 8 Possible malfunctioning 9 Technical features...
® ® 1 Introduction This manual contains information for users of the Niky 600/800 models. You are advised to read this handbook carefully before installing your uninterruptible power supply, meticulously following the instructions given herein. The UPS NIKY is only been made for civil or industrial use; it is not in conformity with the standards for electro-medical equipment.
Niky 600/800 3 Installation • Take your UPS out of its packing. • Make sure the mains supply voltage is identical to the one indicated in the label placed on the rear of the UPS. • Switch on your UPS with the ON/OFF button and check it operates correctly with the mains (green LED on).
Page 4
® 5 Overload and self-shutdown Your UPS is equipped with a system to measure the power delivered at the outlet; when this exceeds the set thresholds, the protection and relative signals are activated; shutdown is automatic with a delay in relation to the size of the overload. Under the line mode the green led will be light.
Software is available as on option for Win98/ME/2000, Novell and Linux, from the website www. ups.legrand.com without charge. User license is included in the product. Telephone protection The NIKY UPS has an integrated, standard RJ11/RJ45 passing telephone connectionthat provides protection for telephone or network equipment (modem, telephones, etc.) against overvoltage...
® 8 Possible malfunctioning The UPS always operates on batteries: • There is no line voltage • Line voltage is out of allowed UPS range • The power supply cable is not correctly connected to mains socket. • The input circuit breaker has to be reset •...
Niky 600/800 9 Technical features 3 100 02 3 100 03 CONSTRUCTION SPECIFICATIONS 3 100 09 3 100 10 3 100 22 3 100 23 Weights 7 Kg. 7,5 Kg. Dimensions L x H x P in mm 95 X 171 X 349 Electronic protection against overloading and short-circuiting.
Page 8
® 9 Technical features 3 100 03 3 100 02 CONSTRUCTION SPECIFICATIONS 3 100 09 3 100 10 3 100 22 3 100 23 Electrical specifications on output with battery operation Rated output voltage 230 V ± 10 % Output frequency 50/60 Hz ±...
Page 9
Niky 600/800 9 Technical features SITE WIRING FAULT AC INPUT AC OUTPUT 3 100 09 3 100 02 3 100 22 3 100 10 3 100 03 3 100 23 1 Status Leds 2 Power Switch 3 Telephone, fax, modem or network protection...